1
Metiri™ Scientific version 2
Portable Smart Energy Meter and Data Logger
Users Manual for Firmware ver: 1.0.65 / published Mar. 22, 2017
For part numbers: COUMET60100SC
WARNING
:
Working with electricity can be dangerous. This product should only be used by people that are comfortable
working with electricy and electronic circuits. By using this product, the user accepts all responsibility for his or her saftey and
property.
QUICK PRODUCT EXPLAINATION
1.
LCD
: Back-lit primary display.
2.
Select Button
: Touch sensitive button with LED touch indicator. Press to scroll through data options or Smart Graph.
3.
Enter Button
: Touch sensitive button with LED touch indicator. Press to return to the main screen. If on the main
screen, will scroll through set-up options.
4.
Aux. Power
: Female socket for device auxilliary power, 5.0Vdc +/-10%. Compatable with USB mini-B Plug.
5.
MicroSD Slot (Scientific Model Only)
: Card slot for recording of measured values. Can accept standard microSD
flash memory formated with FAT32. Metiri™
-S will automatically detect card, create a CVS file, and start writing
measured data.
6.
Source Wires
: Connect to power source or battery up to +60Vdc. Current flowing from Source to Load is considered
positive current. Forward continuous current should never exceed 50 amperes.
7.
Load Wires
: Connect to power load or battery up to +60Vdc. Current flowing from Load to Source is considered
negative current. Negative continuous current should never exceed 50 amperes.
8.
In Line Fuse (Sold Separately)
: The Metiri™ products do not provide protection against
excessive current. A fuse
installed in series with the positive Source Wire is required. Current should never exceed the current specified in the
Safe Operating Area graph.
www.
.com
1.800.561.8187