Installation Manual
3.0 Safety
3.2 Grounding
l
To
provide
protection
against
electrical
surges
induced
by
lightning,
static
charges,
or
any
other
cause,
the
camera
and
cabling
system
must
be
properly
grounded
to
earth.
For
installation
on
a
building,
the
camera
must
be
bonded
(that
is,
provided
with
a
low
impedance
connection)
to
the
building’s
structural
earth
ground
system.
For
installation
on
a
metal
pole
with
a
proper
ground
system
at
the
base,
the
camera
must
be
bonded
to
the
pole.
For
installation
on
a
non-grounded
or
insulated
support,
the
camera
must
be
grounded
with
an
adequate
ground
strap
or
wire
between
the
camera
and
a
nearby
ground
sys-tem,
or
to
a
ground
system
installed
at
the
base
of
the
support.
Failure
to
adequately
ground
the
cam-era
may
lead
to
failure
of
the
camera.
This
applies
to
low
voltage
(24
V
AC
and
PoE
cameras)
as
well
as
to
120
V
AC
cameras.
l
Failures
due
to
surges
are
not
covered
by
the
warranty,
as
they
are
not
due
to
defects
in
material
or
workmanship,
and
it
is
the
installer’s
responsibility
to
meet
these
grounding
requirements.
Note: Refer to
Surge Protection Devices for additional information on
grounding and surge protection concepts.
8
Summary of Contents for 3490HD Series
Page 2: ......
Page 4: ......
Page 19: ...Installation Manual 9 0 Installation 9 1 Typical Wall Mount Installation 19 ...
Page 20: ...Installation Manual 9 0 Installation 9 2 Typical Pole Mount Installation 20 ...
Page 27: ......
Page 28: ...Installation Manual For more information please visit us at www CostarHD com 28 ...