10.1 Backlight Auto-off
The backlight of LS-R700 goes off automatically when any operation key is
not touched for programmed period of time.
> Main Menu > System > System Settings > Start-up
> Backlight Auto-off > Select the duration
(Disable, 1 minute, 5 minutes, 10 minutes, 30 minutes, 60 minutes, 120
minutes, 240 minutes)
10.2 Select a Language
Select a display language from English, Japanese and Chinese
> Main Menu > Language > Select a language
> ”Changing language. OK to continue?” >
Yes
> “Changing language. Do not shut off the power.”
Language will be changed to the selected one.
1
1
1
1
F
F
o
o
r
r
M
M
a
a
i
i
n
n
t
t
a
a
i
i
n
n
i
i
n
n
g
g
R
R
e
e
l
l
i
i
a
a
b
b
l
l
e
e
T
T
e
e
s
s
t
t
R
R
e
e
s
s
u
u
l
l
t
t
s
s
11.1 Daily Inspection Points
Let the power on for 5 minutes or longer for a warm-up before starting inspections.
1) Check Filter/Mist Separator
Drain any accumulated water and check the conditions
of the element.
Look for water/oil residues around the exhaust port.
2) Check the test pressure.
Make sure that the regulator is adjusted to the correct
pressure.
3) Pass/Fail Check
Run a known good part on the machine to see the part
passes. Then, apply a properly rated Leak Master and
run another test to see the part fails.
Water, oil, or other contaminants entering the
Leak Tester through the air pressure source
causes the largest majority of breakdowns in
the Leak Tester.
If contaminants are found in the oil mist
separator, it is strongly recommended to
install an air dryer or additional in-line filters.
Once the Leak Tester is contaminated, the
pneumatic circuit will have to be overhauled
for cleaning, and DPS replacement may be
required.