Warranty
Table 4.9 Warranty (LHA10F-3R3-Y, LHA10F-
O
)
Cooling
Method
Voltage
Mounting
Method
Average ambient
temperature (year)
Warranty
Io
[
75%
75%<Io
[
100%
Convection
3.3 - 12V
A,B,C,
D,E
Ta=45
C
or less
5years
5years
Ta=55
C
5years
3years
F
Ta=40
C
or less
5years
5years
Ta=50
C
5years
3years
15, 24V
A,C,E,F
Ta=45
C
or less
5years
5years
Ta=55
C
5years
3years
B,D
Ta=50
C
or less
5years
5years
Ta=60
C
5years
3years
Forced air 3.3 - 24V
A,B,C,
D,E,F
Ta=60
C
or less
5years
5years
Ta=70
C
5years
3years
Table 4.10 Warranty (LHA15F-3R3-Y, LHA15F-
O
)
Cooling
Method
Voltage
Mounting
Method
Average ambient
temperature (year)
Warranty
Io
[
75%
75%<Io
[
100%
Convection
3.3 - 12V
A,C,E,F
Ta=40
C
or less
5years
5years
Ta=50
C
5years
3years
B,D
Ta=45
C
or less
5years
5years
Ta=55
C
5years
3years
15, 24V
A,D,E,F
Ta=45
C
or less
5years
5years
Ta=55
C
5years
3years
B,C
Ta=50
C
or less
5years
5years
Ta=60
C
5years
3years
Forced air 3.3 - 24V
A,B,C,
D,E,F
Ta=60
C
or less
5years
5years
Ta=70
C
5years
3years
Table 4.11 Warranty (LHA30F-3R3-Y, LHA30F-
O
)
Cooling
Method
Voltage
Mounting
Method
Average ambient
temperature (year)
Warranty
Io
[
75%
75%<Io
[
100%
Convection 3.3 - 24V
A,B,C,
D,E,F
Ta=40
C
or less
5years
5years
Ta=50
C
5years
3years
Forced air 3.3 - 24V
A,B,C,
D,E,F
Ta=50
C
or less
5years
5years
Ta=60
C
5years
3years
Table 4.12 Warranty (LHA50F-3R3-Y, LHA50F-
O
)
Cooling
Method
Voltage
Mounting
Method
Average ambient
temperature (year)
Warranty
Io
[
75%
75%<Io
[
100%
Convection
3.3, 5, 24,
36, 48V
A,C
Ta=40
C
or less
5years
5years
Ta=50
C
5years
3years
B,D,F
Ta=35
C
or less
5years
5years
Ta=45
C
5years
3years
E
Ta=30
C
or less
5years
5years
Ta=40
C
5years
3years
12, 15V
A
Ta=40
C
or less
5years
5years
Ta=50
C
5years
3years
B,C,D,F
Ta=35
C
or less
5years
5years
Ta=45
C
5years
3years
E
Ta=30
C
or less
5years
5years
Ta=40
C
5years
3years
Forced air 3.3 - 48V
A,B,C,
D,E,F
Ta=50
C
or less
5years
5years
Ta=60
C
5years
3years
Table 4.13 Warranty (LHA75F-3R3-Y, LHA75F-
O
)
Cooling
Method
Voltage
Mounting
Method
Average ambient
temperature (year)
Warranty
Io
[
75%
75%<Io
[
100%
Convection
3.3, 5V
A,B,C
Ta=30
C
or less
5years
5years
Ta=40
C
5years
3years
D,E,F
Ta=25
C
or less
5years
5years
Ta=35
C
5years
3years
12 - 48V
A,B,C
Ta=40
C
or less
5years
5years
Ta=50
C
5years
3years
D
Ta=25
C
or less
5years
5years
Ta=35
C
5years
3years
E,F
Ta=35
C
or less
5years
5years
Ta=45
C
5years
3years
Forced air 3.3 - 48V
A,B,C,
D,E,F
Ta=50
C
or less
5years
5years
Ta=60
C
5years
3years
Table 4.14 Warranty (LHA100F-
O
)
Cooling
Method
Voltage
Mounting
Method
Average ambient
temperature (year)
Warranty
Io
[
75%
75%<Io
[
100%
Convection
5V
A,B,C
Ta=30
C
or less
5years
5years
Ta=40
C
5years
3years
D,E,F
Ta=25
C
or less
5years
5years
Ta=35
C
5years
3years
12 - 48V
A,B,C
Ta=40
C
or less
5years
5years
Ta=50
C
5years
3years
D,E,F
Ta=35
C
or less
5years
5years
Ta=45
C
5years
3years
Forced air
5 - 48V
A,B,C,
D,E,F
Ta=50
C
or less
5years
5years
Ta=60
C
5years
3years
Table 4.15 Warranty (LHA150F-
O
)
Cooling
Method
Voltage
Mounting
Method
Average ambient
temperature (year)
Warranty
Io
[
75%
75%<Io
[
100%
Convection
12V
A,B,C
Ta=30
C
or less
5years
5years
Ta=40
C
5years
3years
D
Ta=20
C
or less
5years
5years
Ta=30
C
5years
3years
E,F
Ta=15
C
or less
5years
5years
Ta=25
C
5years
3years
24 - 48V
A,B,C
Ta=40
C
or less
5years
5years
Ta=50
C
5years
3years
D,E
Ta=30
C
or less
5years
5years
Ta=40
C
5years
3years
F
Ta=20
C
or less
5years
5years
Ta=30
C
5years
3years
Forced air 12 - 48V
A,B,C,
D,E,F
Ta=50
C
or less
5years
5years
Ta=60
C
5years
3years
Table 4.16 Warranty (LHA300F-
O
-Y)
Cooling
Method
Voltage
Mounting
Method
Average ambient
temperature (year)
Warranty
Io
[
75%
75%<Io
[
100%
Convection
12V
A,B,C
Ta=25
C
or less
5years
5years
Ta=35
C
5years
3years
D,E
Ta=20
C
or less
5years
5years
Ta=30
C
5years
3years
F
Ta=10
C
or less
5years
5years
Ta=20
C
5years
3years
24, 48V
A,B,C
Ta=40
C
or less
5years
5years
Ta=50
C
5years
3years
D
Ta=35
C
or less
5years
5years
Ta=45
C
5years
3years
E,F
Ta=20
C
or less
5years
5years
Ta=30
C
5years
3years
Forced air 12 - 48V
A,B,C,
D,E,F
Ta=50
C
or less
5years
5years
Ta=60
C
5years
3years
AC-DC Power Supplies Open Frame
Instruction Manual
LHA-31
May 26, 2022