Accessories and consumables
The following parts are available as accessories and consumables for CTR A:
Fault tracing
Fault symptom
Probable cause
Actions
Premises not
dehumidified/low
capacity.
Depending on the situation,
the cause of the problem
could be incorrect
installation, e.g. because of
obstructed wet air hose,
clogged filter, incorrect
settings on the machine or
machine fault.
Perform fault tracing as follows until the
problem has been identified:
Check the installation - check that the wet
air hose is not obstructed, that the dry air
damper is in the correct position and that
the hose used on the dry air side is not
trapped or clogged. Ensure that the air flow
is correct.
If the air flow is weak, check the process air
filter and replace if necessary.
The drier does not
start.
The drier is set to Hyg.
without the hygrostat
connected.
Connect a hygrostat, or switch to Man.
mode.
The rotor rotates
anti-clockwise (seen
through the dry air
outlet) or not at all.
Fault with rotor motor or
motor capacitor.
Contact the dealer for repair.
No air flow, low air
flow
Fault with fan or fan
capacitor.
Contact the dealer for repair.
Part number
Designation
01100
Hygrostat, HR1-5
1002720
Process air filter