VIPER (E) LOW OVERRUN
Operator’s Manual
Release Date: October 26, 2015
Publication Number: 621360241LOEWOP
Revision Date: January 09,2017
Revision: C
Visit the Cornelius web site at www.cornelius.com for all your Literature needs.
Page 1: ...OVERRUN Operator s Manual Release Date October 26 2015 Publication Number 621360241LOEWOP Revision Date January 09 2017 Revision C Visit the Cornelius web site at www cornelius com for all your Liter...
Page 2: ...g occurrences including but not limited to 1 other than normal and proper use and normal service conditions with respect to the Product 2 improper voltage 3 inadequate wiring 4 abuse 5 accident 6 alte...
Page 3: ...trol System Overview 4 Beginning Operation 4 Basic Operation 5 Dispensed Product Throughput 6 Barrel Status Lights 6 Control Panel Display 6 Control Panel menu Buttons 7 Replenishing Supplies 8 Syrup...
Page 4: ...Specifications 14...
Page 5: ...equipment damage CAUTION Indicates a potentially hazardous situation which if not avoided MAY result in minor or moderate injury or equipment damage SAFETY TIPS Carefully read and follow all safety me...
Page 6: ...ea around the unit clean and free of clutter FAILURE TO KEEP THIS AREA CLEAN MAY RESULT IN INJURY OR EQUIPMENT DAMAGE SHIPPING AND STORAGE WARNING Do not use dispense spigot to lift or move unit as th...
Page 7: ...on CART INFORMATION AND MOUNTING The Viper unit may be mounted on a mobile cart Cornelius part no 620043075 for 2 barrel unit 620053990 for 3 barrel unit and 620046556 for 4 barrel unit which allows s...
Page 8: ...is set up by the service provider to perform the tasks necessary to operate the unit No additional changes to these settings should be needed The control system also keeps track of diagnostic informat...
Page 9: ...running in the normal state the unit displays this screen The unit powers up in an off condition To begin normal operation perform the steps in Table 1 Table 1 Step Action Procedure 1 Open the mercha...
Page 10: ...machine is operational and the minimum throughput as described in Table 2 is not met on a per barrel basis product should be dispensed and discarded to increase throughput and help assure that product...
Page 11: ...ere are up to five buttons that are activated on a screen to provide various functions using the control system Each button that is active has a label directly above it The label describes what the bu...
Page 12: ...l to the scribe line on the faceplate as shown in Figure 6 3 When the barrel is full turn on refrigeration When refrigeration shuts off the product is ready to serve Relief Valve FCB Product Level FUB...
Page 13: ...or from the BIB 2 Pull the connector sideways to disengage the line from the bag connector 3 Place a new BIB on the rack and open the cardboard flap Be careful not to puncture the bag with any sharp o...
Page 14: ...t Minimum CO2 pressure to the Viper unit is 75 psig WATER Viper requires a minimum water flow rate of 100 gal per hr for a 2 barrel unit Minimum water pressure is 25 psig Maximum water pressure to the...
Page 15: ...ambient temperature higher than 75oF the times may increase as the ambient temperatures increases Viscosity Setting The lowest possible viscosity settings are recommended to achieve desired drink qual...
Page 16: ...y all external surfaces with a clean soft cloth Remove the drip tray if applicable and wash with a mild soap solution Dry the tray thoroughly and replace it CAUTION Do not use chlorine based solutions...
Page 17: ...arrel Status menu A Sleep time set B Clock incorrectly set C No or incorrect wakeup time set A Check programming B Check programming C Check programming Barrel Status OFF A Not activated B Error has s...
Page 18: ...low cap single compressor 100 gal per hr at 25psig min flowing pressure 25 p s i g min 90 p s i g 0 62 MPa max Ventilation Clearance Standard Condenser 2 on both sides or back 12 on top of the unit E...
Page 19: ......