Problems and Troubleshooting
Before looking for problems with the dispensing equipment, first check:
-
Is the electricity to the device interrupted?
-
Is the flow of water to the device interrupted?
-
Are the beverage containers empty?
-
Is the CO
2
-cylinder empty?
Type of problem
Cause
Remedy
Beverage too warm,
Condenser dirty
Use brush to clean
Compressor running
condenser louvres
Too much beverage
Note out-put capacity
Being dispensed
Beverage too warm,
Compressor defective
Call service technician
compressor not running
Electric control defective
Call service technician
Beverage foams at a tap
Syrup stored too long
Connect container
and enriched with CO
2
with fresh product
Beverage foams at all taps
CO
2
-pressure too high
Set pressure
All Syrup
Connect container
enriched with CO
2
with fresh product
All beverage too warm
Check storage temp
See “Beverage too warm ...”
Tap just outputs
Carbonator pump is
Check if water feed line is
concentrate
not running
open
Check water flow pressure
of 0.2 MPa (2 bar)
Check whether the carbonator
motor is running; if not,
Call service technician
CO
2
-volume in the
Air in carbonator
Bleed air
beverage to low
Too much beverage
Watch output capacity
being dispensed
CO
2
-cylinder empty
Change CO
2
-cylinder
Globe valve on CO
2
-
Open globe valve
cylinder closed
Valve on pressure
Open valve
regulator closed
CO
2
-pressure too low
Adjust pressure
Water temperature
Adjust to lower
too high
temperature
Too much or not enough
Regulator in tap
Call service technician
syrup in beverage
is clamping
(only post-mix)
Delivery pressure for
Adjust CO
2
-pressure
syrup too low or too high