Cornelius Linus 120 Manual Download Page 1

 

 

 

Linus 

16

1. 

Introduction 

Our foremost aim is to produce a quality product. If you should encounter any difficulty which these operating 

instructions do not help you with, call or write us. We will be glad to be of assistance. If you write, please 

include the model and serial number of the device. 

Our address: 

IMI Cornelius Deutschland GmbH 

 

Carl-Leverkus-Strasse 15 

 

D-40764 Langenfeld, Germany 

 

Tel.: +49 (0) 2173 793-0 

 

Fax: +49 (0) 2173  774 38 

 

Internet: www.imi-cornelius.de 

2. 

Safety Regulations 

2.1 

General Safety Regulations 

This device is of leading-edge design and manufacture. If used and maintained in accordance with these 

operating instructions, it will be safe to operate. Please comply with the following safety instructions to avoid 

hazards and damage. 

The device must be in satisfactory condition whenever operated. Any modifications which detrimentally affect 

the safety of the device are therefore strictly prohibited. Please contact your service company if you wish to 

obtain more information about safety. 

No safety equipment (such as safety valves, overload protection devices, etc.) is to be removed, modified or 

put out of commission (risk of injury or death!). 

Take care that only authorized persons work on the device and that the operators are trained. Make certain that 

no unauthorized persons change the settings on the device or tamper with it. 

You are obligated to check the device on a daily basis for externally discernible damage and defects. 

Immediately report modifications which affect safety and function to the service company nearest you. 

Note that only original CORNELIUS replacement parts and accessories which have been checked and 

approved are to be used. IMI Cornelius Deutschland GmbH assumes no liability whatsoever for damage 

resulting from the use of non-original parts and accessories or from improper handling. 

2.2 

Safety Instructions Electricity 

An electric shock may be fatal or result in serious injury. For this reason, any unauthorized tampering is strictly 

prohibited. 

Always pull out the mains plug before any cleaning work on or near the device. As delivered, it features a 

moulded earthing-pin plug and it must be connected to a socket outlet with an earthing contact. This socket 

outlet must be in reach ever! If no appropriate socket outlet with an earthing contact is available, the 

connection must be made by authorized persons only, with the regulations applicable at the installation site 

(EN standards in Europe, for example) being observed. The change of original spare parts must be 

implemented by authorised Personal according to BGVA3 and VDE0701. 

2.3 

Safety Instructions CO

2

Place the carbon dioxide cylinder in an upright position next to the workstation and secure it against falling 

over. Protect it against heat (e.g., against sunshine). Minimum distance from heater 0.5 m. Please only use food 

approved carbon dioxide. Escaping carbon dioxide is heavier than air and may present danger of suffocation if 

Summary of Contents for Linus 120

Page 1: ...eck the device on a daily basis for externally discernible damage and defects Immediately report modifications which affect safety and function to the service company nearest you Note that only origin...

Page 2: ...its overheating and being destroyed Always make certain that no intake or discharge vents are covered MiniLinus Linus 40 Linus 60 Linus 80 Linus 120 Heat output in watt 481 690 1239 1716 1900 Air flow...

Page 3: ...egulator Check the CO2 pressure at the pressure regulator Set the CO2 pressure by turning the control screw at the regulator valve Clockwise to increase the pressure Counter clockwise to reduce the pr...

Page 4: ...stalled which go conform to the instructions for compressed gas tanks and filling equipments Guide for operating safety Storing compressed gas tanks for Dispensing units the following Instructions hav...

Page 5: ...uring cleaning jobs Follow the instructions of the sanitisation agents manufacturer The liquefier louvres must be cleaned at regular intervals which vary according to the amount of contamination at th...

Page 6: ...a tap Product stored too long Connect container and enriched with CO2 with fresh product CO2 pressure too high Set pressure Beverage to warm Check storage temperature CO2 volume in the CO2 pressure to...

Page 7: ...ing in watt 291 450 744 1106 1400 in kcal h 250 388 640 951 1204 Number of cooling coils Bier 1 1 1 or 2 2 2 Dimensions in mm Height 413 385 440 430 430 Width 326 395 426 535 580 Depth 405 310 320 346...

Page 8: ...Linus 23 12 Flow Chart 12 1 Flow Cart with Regulator Valve for Units with Single Valve 12 2 Flow Cart with Air Compressor for Units with Single Valve...

Page 9: ...Linus 24 12 3 Flow Cart with Regulator Valve for Units with Double Valve 13 Circuit Diagram 13 1 Circuit Diagram for Units with mechanical Controller...

Page 10: ...ith electrical Controller C1 Starting Capacitor N1 Temperature Controller F1 Thermal Protection R2 Temperature Probe K1 Starting Relay 11 12 13 Mains Voltage Input M1 Compressor 6 8 Compressor Fan M2...

Page 11: ...und 120 with electrical Controller C1 Starting Capacitor N1 Temperature Controller F1 Thermal Protection R2 Temperature Probe K1 Starting Relay 11 12 13 Mains Voltage Input M1 Compressor 6 8 Compress...

Page 12: ...Linus 27 14 Sprengzeichnungen Exploded drawings Mini Linus...

Page 13: ...lschraube Knurled Head Screw 10 220055093 Vibrationspuffer Buffer 11 220055888 Schnellbefestiger Quick Catch 12 141647504 Netzkabel Power Cord 13 440000287 Kompressor Compressor 14 220110285 Halterung...

Page 14: ...Linus 29 Linus 40...

Page 15: ...14 220055107 Deckel Cover 15 149883201 R ckwand Rear Panel 16 137351000 Temperaturregler Temperature Control mit Temperaturf hler with Temperature Probe 17 440000205 Kompressor Compressor 440000415 S...

Page 16: ...Linus 31 Linus 60...

Page 17: ...Hahnschaftisolierung Beer Valve Insulation 10 197245250 Netzkabel Power Cord 11 440000207 Kompressor Compressor 12 440000419 Startrelais Start Relay 13 440000535 Anlaufkondensator Overload Protection...

Page 18: ...Linus 33 Linus 80...

Page 19: ...Hahnschaftisolierung Beer Valve Insulation 10 197245250 Netzkabel Power Cord 11 440000208 Kompressor Compressor 12 440000421 Startrelais Start Relay 13 440000540 Anlaufkondensator Overload Protection...

Page 20: ...Linus 35 Linus 120...

Page 21: ...Beer Valve Insulation 10 197245250 Netzkabel Power Cord 11 440000218 Kompressor Compressor 12 440000409 Startrelais Start Relay 13 440000469 berlastschutz Starting Capacitor 14 440000528 Anlaufkondens...

Reviews: