IDC 255 Progate Drive Thru Installation Manual
© 2006, IMI Cornelius Inc.
- 29 -
Publication Number: 621057419INS
N
O
C
ARBONATED
W
ATER
Does carbonator
pump start when
unit is turned on?
1. Check the carbonator pump connection to
E-Board in E-Box
For unit with TF1, Is
water line plugged
into a carbonated
water port on TF1?
No Carbonated Water
Plug water line into carb water port
on TF1.
Is incoming
water
restricted?
Is there a power
connection to
carbonator
pump?
1. Check whether or not there is
power across carbonator power cord
on E-Board in E-Box.
2. Change carbonator power cord
on E-Board in E-Box.
1. Restore recommended water flow.
1. Replace carbonator pump.
1. Check lines
2. Replace carbonator
pump.
Yes
Yes
Yes
No
No
No
Yes
Yes
No
No
Is pump
motor
running?