IDC 255 Progate Drive Thru Installation Manual
© 2006, IMI Cornelius Inc.
- 25 -
Publication Number: 621057419INS
N
O
I
CE
D
ISPENSE
IN
M
ANUAL
M
ODE
NO ICE DISPENSE IN MANUAL
MODE
Is manual/
automatic rocker switch
in the manual position
1. Set the machine to
manual mode by pressing
the manual/automatic rocker
switch
No
Is lighted green push
button on
Do drink valves
operate
No
1. Check key lock out
switch
2. Check transformer for
power
3. Check all connections
from the terminal board to
the push button
Is ice
present in the
ice chute
1. Check the
connector between
the control box and
the E - Box
Is ice being
dispensed in
auto mode
No
Is Ice chute
switch enabled or
disabled
Disabled
No
Yes
Enabled
1. Check magnetic switch in switch housing
2. Check for magnet in ice chute cover
3. Validate magnet distance from magnetic switch
for activation to occur
4. Check ice chute disable switch ensuring that relay
1 is activating
5. Check transformer outputs wiring
Yes
Is the
machine inlet
pressure greater
than 35 PSI
1. Check air supply shut off outside the E-Box
2. Check air supply line
3. Check pneumatic cylinder for free movement
1. Check the connector between the
control box and the E-Box.
2. Check relay 3 in the E-Box for
power (terminal 3&4).
3. Check pneumatic solenoid.
Does the agitator run
when push button is
pressed
1. Check the red LED on the
E - Box board
2. Ensure that relay two in the
E-Box is activating
1. Check the electrical
connection from the
portion control board to
the solenoid valve
2. Check pneumatic
solenoid
3. Check relief valve
No
Yes
No
No
Yes
1. Check relay 1 in the E-Box.
The small post on the right hand
side should be retracted
Yes