Agitation Time
The software coding for the progate system involves a direct relationship between the dispense time and
the agitation time.
The relationship is expressed below.
Agitation Time (A
T
) = Dispense Time (D
T
) x Agitation Ratio
2
(R
A
)
Dispense Time (mS)
Agitation Ratio
Agitation Time (mS)
50
10
500
70
10
700
90
10
900
110
10
1100
130
10
1300
150
10
1500
170
10
1700
190
10
1900
210
10
2100
230
10
2300
Dispense Time (mS)
Agitation Ratio
Agitation Time (mS)
50
16
800
70
16
1120
90
16
1440
110
16
1760
130
16
2080
150
16
2400
170
16
2720
190
16
3040
210
16
3360
230
16
3680
Dispense Time (mS)
Agitation Ratio
Agitation Time (mS)
50
28
1400
70
28
1960
90
28
2520
110
28
3080
130
28
3640
150
28
4200
170
28
4760
190
28
5320
210
28
5880
230
28
6440