background image

8

92181INS

CHE

CK

VA

LV

E

CA

RB

WA

T

E

R

S5

8

S8

WA

T

E

R

MA

N

IF

O

LD

6

S6

S

Y

RUP

TA

N

K

S

FAUCETS VIEWED FROM FRONT OF UNIT

S7

S4

S3

S2

1

2

3

4

5

7

1

2

3

4

5

6

S1

S2

S3

S4

S5

S6

S1

CW

CW

15

--50

P

S

IG

60

--100

P

S

IG

RE

M

O

T

E

R

E

FR

IG

ER

A

T

IO

N

SYSTEM

CA

RB

ONA

TOR

F

IL

T

E

R

OP

T

IONA

L

PR

ESSU

R

E

RE

GUL

A

TO

R

RE

GUL

A

TO

R

F

OR

DI

E

T

OR

R

O

O

T

BEER

RE

GUL

A

TO

RS

CO

TA

NK

2

5-

-1

5

PSIG

WA

T

E

R

*

ITEM

S

O

U

T

SID

E

BR

O

KEN

LI

N

E

S

A

R

E

NOT

INCL

UDE

D

W

IT

H

UNI

T.

*

--

F

OR

NON

--C

A

R

B

O

NA

T

E

D

DRI

NK

(S

)/

P

LUG

APPR

O

P

R

IA

T

E

W

A

T

ER

M

A

N

IFO

LD

O

U

TL

E

T.

FA

UCE

T

S

PO

TABL

E

WA

T

E

R

SU

PPL

Y

7

8

S7

S8

CO2

1

2

3

4

F4

F3

F2

F1

FL

A

V

O

R

TA

N

K

S

30

PSIG

FIGURE 7. FLOW DIAGRAM (”B” UNIT WITH EIGHT BEVERAGE FAUCETS)

Summary of Contents for Enduro-200

Page 1: ...12 1 2 1979 or an approved vacuum breaker or other such method as proved effective by test Water pipe connections and fixtures directly connected to a potable water supply shall be sized installed and...

Page 2: ...S WITH BUILT IN COLD PLATE 14 FLAVOR SYRUPS DO NOT DISPENSE 14 FLAVOR DISPENSES FOR MORE THAN 1 SEC 14 FLAVOR DISPENSES MORE THAN 5 OZ 14 WARRANTY 15 LIST OF FIGURES FIGURE 1 DRIP TRAY DRAIN ASSEMBLY...

Page 3: ...of ice which jam up inside the hopper will cause failure of the agitator motor and damage to the hopper If bagged ice is used it must be carefully and completely broken into small cube sized pieces b...

Page 4: ...nes 3 DRIP TRAY DRAIN ASSEMBLY see Figure 1 Route the drain tube to an open drain with the end of the tube above the flood level of the drain Use the tubing fittings clamps and insulation provided wit...

Page 5: ...e ice dispensing rate especially desirable when using glasses or other containers with small openings Adjustment can be made by sliding the restrictor plate up or down with nuts loosened to obtain the...

Page 6: ...8 12 9 3 1 2 9 3 16 11 5 8 23 21 1 4 29 30 11 16 REMOVABLE SINK RECOMMENDED COUNTER OPENING SIZE 9 X 12 FOR UTILITIES AND BEVERAGE TUBING OPENING CAN BE LOCATED ANYWHERE WITHIN SHADED AREA TO FRONT T...

Page 7: ...S3 S2 S1 3 COLD PLATE CARBONATOR FILTER OPTIONAL PRESSURE REGULATOR CO2 Cylinder FAUCETS POTABLE WATER SUPPLY S6 W3 COLDPLATE INLET CONNECTIONS F2 F3 2 1 FAUCETS VIEWED FROM THIS SIDE ITEMS INSIDE BR...

Page 8: ...COLD PLATE CARBONATOR FILTER OPTIONAL PRESSURE REGULATOR CO2 Cylinder FAUCETS POTABLE WATER SUPPLY COLDPLATE INLET CONNECTIONS S5 S4 2 1 FAUCETS VIEWED FROM THIS SIDE ITEMS INSIDE BROKEN LINE INCLUDE...

Page 9: ...S2 INSTALL FOR NON CARB AS REQUIRED FAUCETS VIEWED FROM THIS SIDE S4 S5 OPTIONAL FOR DIET DRINKS OR ROOT BEER 5 15 PSIG S6 4 S7 S8 S9 S10 W3 COLDPLATE INLET CONNECTIONS W1 W2 W4 9 8 7 10 S3 S2 S4 S5...

Page 10: ...E REFRIGERATION SYSTEM CARBONATOR FILTER OPTIONAL PRESSURE REGULATOR REGULATOR FOR DIET OR ROOT BEER REGULATORS CO TANK 2 5 15 PSIG WATER ITEMS OUTSIDE BROKEN LINES ARE NOT INCLUDED WITH UNIT FOR NON...

Page 11: ...PENSE SWITCH BLACK WHITE G R E E N G R E E N TO HINGE BLK BLACK R E D KEY SWITCH TO BEVERAGE VALVES MOTOR HEATER AGITATOR MOTOR B L A C K B L A C K YELLOW NO NC L1 NC NO COM N L2 G R E E N B L U E TO...

Page 12: ...ENOID OPTIONAL BEVERAGE TRANSFORMER MOTOR HEATER LIGHT STARTER BALLAST OPTIONAL LOW ICE LEVEL LIGHT OPTIONAL BEVERAGE VALVES OPTIONAL BEVERAGE VALVES N O L N C C VEND SWITCH G N BEVERAGE PANEL TIMER L...

Page 13: ...B L A C K W H I T E COM WHITE BLACK LIGHT L O A D LT BLUE GRN TO HINGE GUSSET BLK LT BLUE LT BLUE T STAT RED BLACK WHITE WHITE WHITE B L A C K W H I T E BLACK W H I T E B L A C K R E D B L A C K G R N...

Page 14: ...TER POWER SWITCH AGITATOR MOTOR GATE SOLENOID OPTIONAL BEV TRANSFORMER MOTOR HEATER OPTIONAL LIGHT OPTIONAL STARTER OPTIONAL BALLAST 3 S R 2 O L 4 BEVERAGE PANEL N O L N C C VEND SWITCH G N TIMER L2 L...

Page 15: ...e symptoms to aid in locating the defect Trouble Probable Cause BLOWN FUSE OR CIRCUIT BREAKER A Short circuit in wiring B Defective gate solenoid C Defective agitator motor GATE DOES NOT OPEN AGITATOR...

Page 16: ...inner nozzle F Defective PC board G Defective harness from keypad H Defective Flow control I Defective solenoid harness J Defective keypad FLAVOR DISPENSES FOR MORE THAN 1 SEC A Dip switch settings o...

Page 17: ...RWICKSHIRE B49 6 EU ENGLAND D 44 789 763 101 D FAX 44 789 763 644 FRANCE D 71 ROUTE DE ST DENIS D F 95170 DEUIL LA BARRE D PARIS FRANCE D 33 1 34 28 6200 D FAX 33 1 34 28 6201 GERMANY D CARL LEVERKUS...

Reviews: