background image

®

Publication Number: TP01054PMC

- 1 -

                                    Rev. 02/03

Copyright © 2003

www.cornelius.com

Cleanliness/Facility and Equipment Maintenance

ED250 PRO GATE - Cleaning Procedures

Supplies

Equipment Needed

•  Two-compartment Pail

•  Two Clean Sponges or towels

Products Needed

Damon

 Procter & Gamble

D.C. Cleaner

Professional Strength Dawn

Ster-O-Kem

Clean Quick Liquid Quaternary Sanitizer

WARNING:

DISCONNECT POWER BEFORE CLEANING!  DO NOT USE METAL SCRAPERS, 
SHARP OBJECTS OR ABRASIVES ON THE ICE STORAGE HOPPER, TOP COVER, 
AND THE AGITATOR DISK, AS DAMAGE MAY RESULT.  DO NOT USE SOLVENTS 
OR OTHER CLEANING AGENTS, AS THEY MAY ATTACK THE PLASTIC METAL.

Daily

CLEAN EXTERIOR SURFACES

Step

Action

1.

Remove the cup rest from the drip tray and remove any foreign material.

2.

Wash the drip tray with cleaning solution.  Rinse drip tray with clean water and allow the solu-

tion to run down the drain.

3.

Check the drip tray for proper drainage.

4.

Wash the cup rest with cleaning solution and rinse in clean water.  Install the cup rest in the 

drip tray.

5.

Clean all exterior surfaces of the Unit with the cleaning solution, then rinse with clean water 

and dry with paper towels or clean cloths.

Daily

CLEAN AND SANITIZE BEVERAGE DIFFUSER

Step

Action

1.

Remove the nozzle from the dispenser by turning and pulling down.

2.

Remove the diffuser from the valve by pulling down.  Place the nozzle and diffuser in the San-

itizer Solution.

3.

Wipe inside the diffuser area using a sanitized cloth and the nylon nozzle brush.

4.

Clean the diffuser and nozzle using the nylon nozzle brush.  Rinse with lukewarm water.

5.

Reinstall the diffuser and nozzle.  Ensure they are located correctly in the machine.