Ice/Beverage Dispenser Installation Manual
Publication Number: 92166INS
- 5 -
© 2004-2015, Cornelius Inc.
10. If the supply cord is damaged, it must be replaced by the manufacturer, it’s service agent or similarly qual-
ified person in order to avoid a hazard.
A
DJUST
W
ATER
-
TO
-S
YRUP
R
ATIO
Figure 1
11. Remove valve cover and install syrup separator over the diffuser and through the nozzle.
12. Hold cup under valve and dispenser beverage for a specific time (i.e. 2 seconds)
13. NOTE: water and syrup must be cold before checking ratios.
14. Adjust carbonated water flow to the desired rate (such as 90 to 100 ml (3 to 3.75 oz.) per second). Turn the
flow adjuster 1/4 of a turn at a time and recheck the flow. To increase reading turn clockwise.
15. Set a syrup flow adjuster to get the desired ratio.
16. Test the valve and adjust until a consistent ratio is delivered three consecutive times.
17. Repeat procedure for other valves.