Cornelius CONTINUOUS FLOW ICEMAKER 1400R Installation Instructions Download Page 1

                               

Continuous Flow Icemaker 1400R Installation Instructions

© 2005-2014, Cornelius Inc.

- 1 -

Publication Number: 630460310INS

INSTALLATION INSTRUCTIONS

C

ONTINUOUS

 F

LOW

 I

CEMAKER

 S

ERIES

 1400R

!

WARNING

:

Disconnect power to the unit before servicing. Follow all lock out/tag out procedures established by the user. Verify all 
power is off to the unit before performing any work.

Failure to comply could result in serious injury, death or damage to the equipment.

This manual covers unpacking and inspection, selecting location, installing unit, and preparing for operation.

The unit is a split system; it consists of a condensing unit, an icemaker and a line kit.

• 

The condensing unit is an outdoor component; it contains the compressor, condenser, receiver and fan motor. It is 
controlled by a low-pressure switch. 

• 

The icemaker is an indoor component; it contains two gear motors, two evaporators, two water level controls and 
two bin thermostats. The bin thermostats control a liquid line solenoid.

• 

Line Kit: precharged 3/8” liquid line and 3/4” suction line.

NOTE:  In a rack refrigeration application, only the ice maker is required (condensing unit and line kit are 

not used). Ice maker installed on a -23° F (-30.56° C) low state saturation temperature (14 psig sat-
uration pressure for R404A) requires the installation of one EPR valve, set at 20 psig downstream 
of the common suction line of WCC-1400R unit. Approved EPR model is ORIT-6-0/50.

R

EMOVE

 U

NITS

 C

ARTON

1.

Keep unit in the upright position, remove carton and pallet from unit and inspect for damage. 

2. Locate startup card either on outside of container or on plastic liner. Fill in proper information and send one 

copy to factory, and other copy to distributor. Postage is prepaid.

C

ABINET

 R

EMOVAL

Condensing Unit

• 

Remove 19 screws and lift upward.

Icemaker

1.

Front Panel 

 

 Remove 4 screws and pull forward.

2.

Top Panel

 – Remove 4 screws and lift upward.

3.

Side Panels

 – Remove 3 screws and pull forward.

4.

Back Panel 

– Should not be removed.

P

REPARATION

 

OF

 I

NSTALLATION

 S

ITE

Condensing Unit

The refrigeration system is air-cooled, it requires airflow, so a well-ventilated area should be chosen. A minimum of 
4 feet must be maintained for air intake and exhaust.

Revision Date: March 18, 2014

www.cornelius.com

Revision: D