background image

TigoStarter K6 

User Manual

 

 

Copyright © 2020 CoreTigo Ltd.

 

 

 
 

Page 

29

 of 

32

 

 

 

be considered CoreTigo’s Confidential Information. It is further understood that use of Feedback, if any, may be 

made by CoreTigo at its sole discretion, and that CoreTigo in no way shall be obliged to make use of any kind of 

the Feedback or part thereof. 

8.

 

Content

. Company shall be solely responsible for any content and data used or optimized by Company by means 

of the Product. UNDER NO CIRCUMSTANCES WHATSOEVER WILL CORETIGO BE LIABLE IN ANY 

WAY FOR ANY CONTENT AND/OR DATA INCLUDING, WITHOUT LIMITATION, FOR ANY ERRORS 

OR  OMISSIONS  IN  ANY  CONTENT  AND/OR  DATA,  OR  FOR  ANY  INFRINGEMENT  OF  THIRD 

PARTY’S RIGHT, LOSS OR DAMAGE OF ANY KIND INCURRED AS A RESULT OF THE USE OF THE 

CONTENT, DATA AND/OR THE PRODUCT. 

9.

 

Support

. During the Evaluation Period, CoreTigo shall make reasonable efforts to provide Company assistance 

via telephone, facsimile or email to answer any questions or concerns relating to the Product. Such assistance 

shall be provided at no charge to Company. 

10.

 

Warranty  Disclaimer

.  COMPANY  ACKNOWLEDGES  THAT  THE  PRODUCT  IS  PROVIDED  “AS  IS”, 

AND  CORETIGO  DISCLAIMS  ANY  AND  ALL  WARRANTIES,  WHETHER  EXPRESS  OR  IMPLIED, 

INCLUDING,  WITHOUT  LIMITATION,  ANY  IMPLIED  WARRANTIES  OF  MERCHANTABILITY  OR 

FITNESS  FOR  A  PARTICULAR  PURPOSE  AND  ANY  WARRANTY  OF  NON-INFRINGEMENT  OF 

THIRD PARTIES’ RIGHTS, INCLUDING INTELLECTUAL PROPERTY RIGHTS.  

11.

 

High Risk Activities

. Company hereby acknowledges that the Product is not fault tolerant and is not designed, 

manufactured or intended for use or resale as on-line control equipment in hazardous or high risk environments 

and activities requiring fail-safe performance (such as in the operation of nuclear facilities, aircraft navigation or 

communication systems, air traffic control, direct life support machines and/or devices, or weapons systems), in 

which the failure of the Product could lead directly to death, personal injury or severe physical or environmental 

damage, and Company hereby agrees not to use or allow the use of the Product or any portion thereof for, or in 

connection with, any such environment or activity. 

12.

 

Limitation of Liability

. TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, CORETIGO, 

ITS OFFICERS, DIRECTORS AND/OR EMPLOYEES, SHALL NOT BE LIABLE FOR DIRECT, INDIRECT, 

SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF ANY PERFORMANCE 

OF  THIS  AGREEMENT  OR  IN  FURTHERANCE  OF  THE  PROVISIONS  OR  OBJECTIVES  OF  THIS 

AGREEMENT,  INCLUDING  BUT  NOT  LIMITED  TO  FOR  ANY  LOSS  OR  DAMAGE  TO  BUSINESS 

EARNINGS,  LOST  PROFITS  OR  GOODWILL,  LOST  OR  DAMAGED  DATA  OR  DOCUMENTATION, 

AND COSTS OF PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES SUFFERED BY COMPANY 

AND/OR ANY ENTITY AND/OR PERSON ARISING FROM AND/OR RELATED/CONNECTED TO ANY 

USE OF THE PRODUCT, EVEN IF CORETIGO IS ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. 

COMPANY’S SOLE RECOURSE IN THE EVENT OF ANY DISSATISFACTION WITH THE PRODUCT IS 

TO  STOP  USING  IT  AND  RETURN  IT  TO  CORETIGO.  IN  ANY  EVENT,  CORETIGO’S  LIABILITY 

Summary of Contents for TigoStarter K6

Page 1: ...TigoStarter K6 User Manual Copyright 2020 CoreTigo Ltd Page 1 of 32 TigoStarter K6 IOLW Master Development Revision 1 0 USER GUIDE...

Page 2: ...ent 13 2 3 2 1 TigoMaster 2TS Development HW setup 13 2 3 2 2 TigoMaster 2TS Evaluation SW use 14 2 4 Connect the TigoAir Device 16 2 4 1 TigoMaster E2 Device Development HW setup 16 2 4 2 TigoMaster...

Page 3: ...gure 13 TigoBridge LEDs labeling 18 Figure 14 Putty configuration window 19 Figure 15 Master UI Menu first image 20 Figure 16 Setting menu 20 Figure 17 Scan result display example 21 Figure 18 W Port...

Page 4: ...ce HW Hardware IF Interface IOLW IO Link Wireless LED Light Emitting Diode PD Process Data SW Software UART Universal Asynchronous Receiver Transmitter W Device IO Link Wireless Device W Master IO Lin...

Page 5: ...e components This user guide will guide you through 1 Setup IO Link Master 2TS IO Link Device TigoAir wirelessly 2 Get Familiar with the TigoEngine SW engineering tools to evaluate IO Link Wireless of...

Page 6: ...2 54mm pitch JTAG cable to a slimmer 2x5 0 05 1 27mm pitch SWD 1 16 Pin to U Art 1 AC DC WALL MOUNT ADAPTER 5V 6W 1 1 5M LONG POWER CABLE 1 Test Plugs Test Jacks quick connect black sheated straight T...

Page 7: ...nection of an IO Link Wireless Master Device to Evaluate IO Link Wireless Enables simple connection of a single IO Link or digital sensor actuator directly to the TigoBridge thus turning those devices...

Page 8: ...vices as described further down in this document o STM32CubeProgrammer enables fast programming using the ST Link debugger provided in the starting kit o CP2108 USB to UART Bridge driver from https ww...

Page 9: ...control with TigoEngine configuration tool 2 Development Connected to PC via the provided Application processor NUCLEO F767ZI control via Master Menu Figure 3 2TS Product Description TigoMaster 2TS c...

Page 10: ...ted with the TigoMaster 2TS Upon installation use the TigoEngine software engineering tool for configuring IO Link Wireless master and devices Reference TigoEngine Installation Guide for TigoMaster 2T...

Page 11: ...ted to PC TigoEngine User Interface 1 Masters View Masters view is intended for connecting a new W Master to the TigoEngine and keeping a record of configured W Masters TigoEngine supports multiple W...

Page 12: ...Click on Scan Tab to open area use scan button on the right side of the view Figure 6 TigoEngine Scan 3 Locate the UID of device needed for pair Hexadecimal representation 4 Select the required W Devi...

Page 13: ...reference for quick and easy ramp up to develop a TigoMaster application Reference TigoMaster SMI API SW Guide for TigoMaster 2TS 2 3 2 1 TigoMaster 2TS Development HW setup The Nucleo board s need to...

Page 14: ...sequence required to flash new Application developed Open the STM32 ST LINK Utility and connect to your device Click on Target Program Verify Browse to CoreTigo_SDK_Release_XX_YY_ZZZZ SDK_Release_Tig...

Page 15: ...erence example With Reference Application Menu it is possible to configure Control and monitor Wireless IO Link link Mainly o Via Setting menu Scan Pair Unpair and monitor Link quality o Via Master Co...

Page 16: ...t using an A to mini B USB cable 2 4 1 TigoMaster E2 Device Development HW setup Figure 11 TigoAir E2 2 4 2 TigoMaster E2 Device Development SW setup To flash the MCU use the ST Link debugger JTAG to...

Page 17: ...ith an IP67 enclosure The TigoBridge converts IO Link to IO Link Wireless The TigoBridge includes an internal antenna and two M12 connectors for data and power TigoBridge is a device that connects a w...

Page 18: ...s LED will alternate between magenta and yellow 5 Plug TigoBridge to an IO Link device sensor actuator Note if TigoBridge cannot connect directly to the device you may use an M12 cable Once connection...

Page 19: ...Master USB connection mentioned previously will also give you access to its UI which is addressable as a Serial COM port at a Baud Rate of 115200 Make sure the Nucleo F767ZI USB marked in Figure 34 i...

Page 20: ...r using the reset button You should now see the following image Figure 16 Master UI Menu first image Use the option numbers to navigate in the menu for example press 1 and then Enter to enter Settings...

Page 21: ...sec and return to the menu for more info on the scan process refer to the IO Link Wireless Master API Guide 1 Figure 18 Scan result display example 2 Show Scan Result this function prints the last sc...

Page 22: ...eset reboot the master will load the last stored configuration and attempt to connect with the configured devices 7 Disable Port this option allows you to remove a wireless port that no longer exist a...

Page 23: ...ameter refer to the IO Link Wireless Master API Guide 1 3 Set Max Retry all Wports this option changes the max_retry parameter and essentially contains the maximum number of retries for a transmission...

Page 24: ...t index subindex AL Write This Function allows ISDU write to Operational Wports Will write the value given entering the wanted port index subindex and Value Set PDOut This Function allows sending Proc...

Page 25: ...cy tests Figure 24 Test Tab 4 1 Test 1 IO Link Wireless Latency In CoreTigo s Latency reference the Cycle time parameter is controlled directly via the max_retry configuration field Set in port config...

Page 26: ...t2 IO Link PER Test PDIn The test triggers PDin Device to Master Test output Arrived Missing PER Figure 26 IO Link Wireless PDIn PER 4 3 Test3 IO Link PER Test PDout The test triggers PDout Master to...

Page 27: ...T PERMITTED UNDER APPLICABLE LAW IF YOU DO NOT AGREE TO BE BOUND BY THIS AGREEMENT PLEASE DO NOT DOWNLOAD INSTALL OR USE THE PRODUCT THE PRODUCT MAY BE USED SOLELY FOR YOUR PERSONAL NON COMMERCIAL PUR...

Page 28: ...Payment Terms Company agrees to compensate CoreTigo for the Evaluation in the amount as set forth in the quotation attached hereto and or associated and referencing this Agreement which shall be paid...

Page 29: ...RIGHTS 11 High Risk Activities Company hereby acknowledges that the Product is not fault tolerant and is not designed manufactured or intended for use or resale as on line control equipment in hazardo...

Page 30: ...cessary safeguards affording the Confidential Information at least the same level of protection that it affords its own information of similar importance to prevent the disclosure of such Confidential...

Page 31: ...y the other party shall certify in writing to the other its compliance with the terms of this Section 17 4 17 5 Without derogating from any of the terms set forth above Company further agrees that fol...

Page 32: ...acknowledgement are null void and of no effect A waiver of any provision will not constitute a continuing waiver of such provision or a waiver of any other provision Failure by either party to demand...

Reviews: