![CoreTigo TigoBridge B1 User Manual Download Page 11](http://html1.mh-extra.com/html/coretigo/tigobridge-b1/tigobridge-b1_user-manual_2667347011.webp)
TigoBridge B1
User Manual
Copyright © 2021 CoreTigo Ltd.
Page
11
of
21
4.3.2. Status LED
Table 2: Status LED
LED Color
Indication
Magenta
Unpaired wireless
Blue
Operational wireless bridge
Green
Operational wired device
Yellow
Non-operational wired device
White
Wireless Error (see Note)
Blinking Green
Firmware update mode
4.4. Pair by Button
The Pair by button is used to replace existing TigoBridge B1 with a new one.
The TigoBridge B1 must be powered off to assure that the TigoMaster disconnects before installing a new
TigoBridge B1.
Pairing Button
currently disabled. To enable, contact CoreTigo Support.
4.5. Electrical Wiring
TigoBridge B1 has two M12 connectors.
•
IO-Link Connector
: 5 pins, A-Coded female connector.
Maximum Current supply to IO-Link device 1L+ port is 1 A when using 24 VDC.
Maximum Current supply to IO-Link device 2L+ port is 2.5 A under 50°C, linearly
de-rated to 1 [A] at 60°C
•
Power Connector
: 5 pins, A-Coded male connector.
Higher voltage than 32 VDC is restricted, as it can damage the TigoBridge.