User and Maintenance Manual
Failsafe hydraulic brake ID 2000N
Model ID 2000N-116
Date: 2014/06/27
Revision: 1.1
www.coremo.it
Page
8
of
25
7.
Installation
THE BRAKE MUST BE INSTALLED WITH THE MACHINE OFF.
Personnel assigned to this work must wear suitable PPE such as gloves, safety footwear and
take any other appropriate precautions to ensure adequate protection and avoid the risk of
injury.
1.
The ID 2000N-116 brake must be installed on a bracket having the same thickness as the disc
minus 2 mm (Figure 1).
The brake must be anchored using three M30 class 12.9 screws and tightening torque of 2300
Nm.
Figure 1
The fixed part which is to support the brake must withstand a tangential force of 126700 N
2.
Connect the brake to the power line using a 1/4” gas fitting. The brake can be supplied on
request complete with Ø8 pipe fitting (H0045) already connected.
3.
Pay attention to the control pressure; the pressure not exceed 220 or drop below 200 bar. The
brake must be powered exclusively using mineral oil hydraulic fluid.
Do not apply the brake without the disc positioned between the brake linings (Photo 1);
failure to follow this rule could result in fingers being crushed and other dangers in
addition to damage to the brake itself.