background image

 
 

CS1060 Temperature & Humidity Sensor

 

User Guide

 

 
 

Long-range, low-power temperature and humidity sensor supporting 
LoRaWAN or Coralink wireless protocols. Ideal for applications in 
smart-building, home automation, metering, and logistics.

 

  

Version: 1.0

 

May 2022

 

Summary of Contents for CS1060

Page 1: ...ty Sensor User Guide Long range low power temperature and humidity sensor supporting LoRaWAN or Coralink wireless protocols Ideal for applications in smart building home automation metering and logist...

Page 2: ...Operating Configuration 6 About LoRaWAN 8 Terminology 8 Device Placement 9 Notes for Proper Use 9 Event Notifications and Reports 10 Reset Notifications 10 Firmware Version 10 Replacing the Batteries...

Page 3: ...ng optimal monitoring and data collection Deploy the sensor in any location where temperature monitoring is required Ensure refrigerators and freezers maintain constant temperature Monitor the tempera...

Page 4: ...indicators is shown in the figure below Figure 2 CS1060 LED Status Indicators Periodically the CS1060 will blink red twice when joining the network Assuming the device is properly registered on an av...

Page 5: ...ctory Reset Holding the button will perform a network or factory reset Network Reset Press and hold the SET button for 10 seconds but less than 25 then release The device will reset all LoRaWAN Settin...

Page 6: ...ion requirements Default Configuration Description Button Presses Continuous Sampling DEFAULT Continuous periodic reporting of temperature and humidity every 15 minutes Battery health check sent once...

Page 7: ...s useful for long term monitoring temperature changes with equipment indicating potential equipment failure Battery life is typically 5 years 3 To change the Sensor configuration 1 Press the button sl...

Page 8: ...nk and downlink messages may be of either confirmed or unconfirmed type Confirmed messages are guaranteed to be delivered but will consume extra wireless bandwidth and battery life These mechanisms ar...

Page 9: ...that it will not fall off or be knocked down Notes for Proper Use 6 The sensor must NOT be submerged 7 For accurate readings do not obstruct the opening on the sensor 8 Do not place the sensor on or...

Page 10: ...ne minute to 44 days Periodic Statistics Report temperature and humidity statistics at regular intervals from one minute to 44 days Statistics reports provide Average values Maximum Minimum values Var...

Page 11: ...UMIDITY SENSOR USE EXTREME CARE AND FOLLOW THE BATTERY REPLACEMENT INSTRUCTIONS CLOSELY DO NOT MIX OLD AND NEW BATTERIES MAKE SURE THE BOTTOM SHELL AND SEALED RUBBER PADS ARE TIGHTLY SECURED OTHERWISE...

Page 12: ...take out the four sealed rubber pads at the base of the device 11 Use a screwdriver to unscrew the screws at the base of the device and remove the base 12 Remove existing batteries and recycle 13 Inst...

Page 13: ...Notification Triggers Define up to six 6 triggers to tailor the temperature humidity monitoring and notification reporting N A See Default Configurations LED Mode LED OFF Stealth Mode LED ON Telemetr...

Page 14: ...C Operating Humidity Range 95 non condensing Temperature Value Resolution 0 1 F C Humidity Value Resolution 0 1 For Indoor and Outdoor Use IP Rating IP67 Typical Temperature Accuracy Maximum Temperatu...

Page 15: ...CS1060 Temperature Humidity Sensor User Guide Page 15 Maximum Humidity Accuracy 77 F 25 C Humidity Range Uncertainty 0 20 3 5 20 80 2 80 100 3 5 41 140 0 72...

Page 16: ...d 6 version 2 Profile 5 Packaging 2 The fields are defined as follows Field name Character Length Description ID 6 Device six 6 character identification code Available options CS1060 Revision A Cora S...

Page 17: ...file with all identifiers to load into their database 0X Custom packaging option Contact Codepoint for further information Example SKUs CS1060 UL US9HT 00 Temperature Humidity sensor for U S region u...

Page 18: ...he dealer or an experienced radio TV technician for help This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful int...