3.  SPECIFICATIONS

Analog Impedance

900 ohms

DC On-Hook Resistance

Greater than 4 megohms between Tip and Ring
at the output of the COT

DC Off-Hook Resistance

960 ohms

Channel Signature

Tip Ring:

(open)

Tip Ground:

162 kohm, 1%

Ring-Ground:

226 kohm, 1%

COT 20-Hz Input Impedance

0.9 REN

COT Ring Detection

The COT channel unit recognizes an ac signal
between tip and ring leads with an amplitude
from 65 Vrms to 104 Vrms and frequency
between 16 Hz and 50 Hz as a ringing signal.
This signal may be superimposed on a dc
component of -36.0 Vdc to -56.5 Vdc applied to
the ring lead with respect to the tip lead.  The
tip lead may or may not be referenced to
ground.  The source impedance of the ringing
signal must be less than 500 ohms.

Operating Temperature & Humidity

-40° F to +150° F (-40°C to +65° C)
5% to 95% (non condensing)

Operating Elevation

-200 ft. to 13,000 ft.
(-60 m to 4,000 m)

Dimensions

Height:

6.75”

(17.2 cm)

Width:

1.00”

(2.5 cm)

Depth:

10.50”

(26.7 cm)

Weight

0.8 lb. (0.4 kg)

Summary of Contents for PairGain PG-Flex FLC-703

Page 1: ...SCRIPTION AND FEATURES 2 2 APPLICATIONS 2 3 SPECIFICATIONS 3 4 CERTIFICATION 4 5 WARRANTY 4 B FUNCTIONAL DESCRIPTION 6 OPERATIONAL CAPABILITIES 4 7 FRONT PANEL 5 C INSTALLATION AND TEST 8 UNPACKING 5...

Page 2: ...lifies troubleshooting Pair Gain Test Controller PGTC Compatibility List 3 only 2 APPLICATIONS 2 01 Subscriber Drop Testing For subscriber drop testing from the central office PG Flex is able to selec...

Page 3: ...signal between tip and ring leads with an amplitude from 65 Vrms to 104 Vrms and frequency between 16 Hz and 50 Hz as a ringing signal This signal may be superimposed on a dc component of 36 0 Vdc to...

Page 4: ...eplace it with another unit and return the faulty unit to PairGain for repair Any modifications of the unit by anyone other than an authorized PairGain representative will void the warranty 5 03 If a...

Page 5: ...as follows 1 Unpack each container and visually inspect it for signs of damage If the equipment has been damaged in transit immediately report the extent of damage to the transportation company and to...

Page 6: ...the COT Shelf All LEDs on the Channel Unit will turn on for approximately second then scan from top to bottom then flash all on then off b After the system has powered up established HDSL synchronized...

Page 7: ...Unit If ringing is present on other lines check for high resistance shorts on the subscriber drop If no high resistance shorts replace the RT Channel Unit 2 If ringing isn t present on a circuit term...

Reviews: