Revision 01
May 30, 1997
Section 363-718-104
PG-Flex FCS-718
PairGain Engineering - Plant Series
Page 17
You must use the cable adapter (PN 120-1111-01) to ensure the subscriber
terminations follow the information shown in Table 15.
Table 15. System 2 Subscriber Terminations
CU*
Circuit
Conn
P2 Tip
Conn
P2 Ring
Tip
Ring
Conn
P4 Tip
Conn
P4 Ring
Circuit
CU*
1
26
1
WH/BL
BL/WH
26
1
1
2
27
2
WH/OR
OR/WH
27
2
2
3
28
3
WH/GN
GN/WH
28
3
3
7
4
29
4
WH/BN
BN/WH
29
4
4
10
(1)
5
30
5
WH/SL
SL/WH
30
5
5
(4)
6
31
6
RD/BL
BL/RD
31
6
6
7
32
7
RD/OR
OR/RD
32
7
7
8
33
8
RD/GN
GN/RD
33
8
8
1
34
9
RD/BN
BN/RD
34
9
1
2
35
10
RD/SL
SL/RD
35
10
2
3
36
11
BK/BL
BL/BK
36
11
3
8
4
37
12
BK/OR
OR/BK
37
12
4
11
(2)
5
38
13
BK/GN
GN/BK
38
13
5
(5)
6
39
14
BK/BN
BN/BK
39
14
6
7
40
15
BK/SL
SL/BK
40
15
7
8
41
16
YL/BL
BL/YL
41
16
8
1
42
17
YL/OR
OR/YL
42
17
1
2
43
18
YL/GN
GN/YL
43
18
2
3
44
19
YL/BN
BN/YL
44
19
3
9
4
45
20
YL/SL
SL/YL
45
20
4
12
(3)
5
46
21
VI/BL
BL/VI
46
21
5
(6)
6
47
22
VI/OR
OR/VI
47
22
6
7
48
23
VI/GN
GN/VI
48
23
7
8
49
24
VI/BN
BN/VI
49
24
8
* The CU numbers in parentheses are for a List 3 or higher LU. The numbers not in parentheses are for a List 1
or 2 LU.
Shaded terminations are used only with 8 channel POTS and DDS CUs.