Section 363-719-102
June 2, 1997
Revision 01
Page 2
PairGain Engineering - Plant Series
PG-Flex FCS-719
2. Specifications
Electrical Characteristics
Power .......................................................................... -48 Vdc CO battery
Environmental
Operating Temperature ................................................ -40° F to +150° F (-40° C to + 65° C)
Operating Humidity ..................................................... 5% to 95% (non-condensing)
Operating Elevation ..................................................... -200 feet to 13,000 feet (-60 m to 4,000 m)
Dimensions
Mounting ..................................................................... 23-inch equipment bay using universal mounting
brackets
Height.......................................................................... 07.00 in. (17.8 cm)
Width .......................................................................... 23.00 in. (58.4 cm)
Depth........................................................................... 11.75 in. (29.9 cm)
Weight......................................................................... 15.00 lbs (06.8 kg)
B. FUNCTIONAL DESCRIPTION
3. Operational Capabilities
3.1
Each system (one Line Unit and one to three Channel Units) can support up to 24 channels. Each
Channel Unit can provide four (4) or eight (8) channels, depending on the service offered. Services
offered are:
Plain Old Telephone Service (POTS)
Integrated Services Digital Network (ISDN)
A label on the FCS-719 shelf indicates numbering for the Line and Channel
Units. When the Line Units are a List 1 or 2, black numbers indicate sequential
Channel Unit numbering 1 through 12. When the Line Units are List 3 or higher,
blue numbers indicate Channel Unit numbering 1 through 3 for each of the
four systems.
3.2
Tables 1 and 2 show how to utilize channels, dependent on the Channel Unit (four or eight channels)
and the type of subscriber service (POTS or ISDN) selected.