Figure 2.  Typical PG-Flex Configuration.

TABLE 1.  PG-FLEX DISTANCES

Loop Length

Wire Gauge

12/24 Channel System

DC Resistance

26 AWG

(0.4 mm)

9.0 kft

(2.8 km)

750 

24 AWG

(0.5 mm)

12.3 kft

(3.8 km)

638 

22 AWG

(0.6 mm)

16.1 kft

(5.0 km)

521 

19 AWG

(0.9 mm)

22.8 kft

(7.0 km)

367 

2.07

Test access may be achieved by p116 V

on the subscriber’s COT tip lead for 1.5 seconds, then
removing the +116 V. Depending on the configuration of
the PG-Flex system, the selected subscriber drop
(assuming a working metallic bypass pair) will be
connected to either the corresponding COT subscriber line
or to the test access bus.

2.08

The test connection will be dropped when -116V

is applied to the subscriber’s COT tip for 1.5 seconds, then
removing the -116 V.

2.09

Test access may also be activated through the

RS-232 Maintenance Port located on the front of the COT
and RT Line Units, using an ASCII terminal.

3.  SPECIFICATIONS

COT Power Supply Input Voltage

-42 to -56 V dc

COT Power Supply Input Power

145 Watts (maximum)

COT Power Supply Input Protection

Fuse (3A GMT)

COT Power Supply Output Voltage

± 130 Vdc (maximum)

COT Power Supply Output Power

100 Watts (maximum)

Operating Temperature & Humidity

-40° F to +150° F (-40° C to +65° C)
5% to 95% (non-condensing)

Operating Elevation

-200 ft to 13,000 ft (-60 m to 4,000 m)

Dimensions

Height:

6.75” (17.2 cm)

Width:

2.00”

(5.1 cm)

Depth:

10.50” (26.7 cm)

Weight

2.0 lbs. (0.9 kg)

Summary of Contents for 150-1312-01

Page 1: ...2 2 APPLICATIONS 2 3 SPECIFICATIONS 3 4 CERTIFICATION 4 5 WARRANTY 4 B FUNCTIONAL DESCRIPTION 6 OPERATIONAL CAPABILITIES 4 7 FRONT PANEL 6 8 TERMINAL MANAGEMENT 7 C INSTALLATION AND TEST 9 UNPACKING...

Page 2: ...A PG Flex system shown in Figure 2 consists of Central Office Terminal COT Two complete systems may be installed in a 19 inch COT Shelf and four complete systems may be installed in a 23 inch COT She...

Page 3: ...criber line or to the test access bus 2 08 The test connection will be dropped when 116V is applied to the subscriber s COT tip for 1 5 seconds then removing the 116 V 2 09 Test access may also be act...

Page 4: ...esentative will void the warranty 5 03 If a unit needs repair call PairGain for a Return Material Authorization RMA number and return the defective unit freight prepaid along with a brief description...

Page 5: ...Section 363 712 100 Revision 02 Page 5 Figure 3 FLL 712 COT Line Unit Block Diagram...

Page 6: ...line 1 margin is below a preset level Off HDSL line 1 margin is above the preset level LOOP 2 SYNC LED Indicator Green HDSL line 2 is in sync between the COT and RT Flashing Green HDSL line 2 is attem...

Page 7: ...choose any of the following options Status Setup Test Inventory Status By selecting the Status option A from the Main Menu the technician can Display System Status to show the equipment installed in...

Page 8: ...Section 363 712 100 Revision 02 Page 8 Figure 4 FLL 712 DB 9 Pin Outs A standard RS 232 DB 9 connector on the front panel provides access to the menu interface feature via a dumb terminal...

Page 9: ...Section 363 712 100 Revision 02 Page 9 Figure 5 Terminal Menu and Display Structure...

Page 10: ...s TABLE 2 FLL 712 COT LINE UNIT TURN UP AND TESTING CAUTION Observe normal electrostatic discharge precautions when handling electronic equipment Do not hold electronic plugs by their connector edges...

Page 11: ...s a problem with the HDSL circuit between the COT and RT assuming the FAULT LED is off 2 COLU and RTLU incompatible That is one is a T1 version and the other is an E1 version a Verify the HDSL circuit...

Page 12: ...re direct indication of the loop attenuation to the 2B1Q signal than the 196 kHz loss The normal range of pulse attenuation is from 1 to 32 dB PPM Indicates the relative offset of the crystal oscillat...

Reviews: