Xenus XSL User Guide
Operational Theory
Copley Controls Corp.
35
2.9.3: CAN Interface Status Indicator Operation
The amplifier status indicator color/blink codes comply with CAN Indicator Specification 303-3 as
described below. Note that green and red codes are often interlaced, each indicating a different
set of conditions. The green codes indicate the CANopen state machine mode of operation (pre-
operational, operational, or stopped). The red codes indicate the status of the physical bus
(warning or error conditions).
CANopen State Machine Mode of Operation
Indicator State Diagram
Blinking green
Pre-operational.
200
ms
off
200
ms
green
Steady green
Operational
off
green
Single flash green
Stopped
green
200
ms
off
1 second
Physical Bus Status
Single flash red
Warning Limit
Reached
red
200
ms
off
1 second
Double flash red
Error Control Event
red
200
ms
off
1 second
200
ms
Triple flash red
Sync Error
red
200
ms
off
1 second
200
ms
200
ms
Steady red
Bus Off
red
off
In addition, the CAN status indicator is turned off when the CAN node ID selector (CAN ADDR) is
set to 0. A setting of 0, which is invalid, shuts down most operations on the CAN interface, and the
light is shut off to indicate this status.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com