Xenus XSL User Guide
Xenus Filter
Copley Controls Corp.
179
E.5.3: Cable Notes
1 Keep the Edge Filter J1 to Xenus J2 cable as short as possible. A typical length is 7 inches.
2 To reduce noise, twisted shielded cable must be used and the signal cables should not be
bundled in the same conduit.
E.5.4: Input (J1) From Amplifier
Mating Connector
Description
Euro-style, 5 position, 5.0 mm pluggable female terminal block.
Manufacturer PN
Wago 721-105/026-047
Wire Size
22 - 12 AWG
Recommended Wire
12 AWG, 600 V
(Shielded cable used for CE compliance)
Wire Insertion/Extraction Tool
Wago 231-131
Connector and tool are included in connector kit XSL-FK.
Pin Description
Pin Signal
Function
1
Ground
Chassis ground and cable shield
2
Phase W
Phase W input from amplifier
3
Phase V
Phase V input from amplifier (use for DC motor connection)
4
Phase U
Phase U input from amplifier (use for DC motor connection)
5
--- No
connection
E.5.5: Output (J2) To Motor
Mating Connector
Description
Euro-style, 4 position, 5.0 mm pluggable female terminal block.
Manufacturer PN
Wago 721-104/026-047
Wire Size
22 - 12 AWG
Recommended Wire
12 AWG, 600 V
(Shielded cable used for CE compliance)
Wire Insertion/Extraction Tool
Wago 231-131
Connector and tool are included in connector kit XSL-FK.
Pin Description
Pin Signal
Function
1
Ground
Chassis ground and cable shield
2
Phase W
Phase W output to motor
3
Phase V
Phase V output to motor (use for DC motor connection)
4
Phase U
Phase U output to motor (use for DC motor connection)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com