3.16: Resolver Interface
XEL/XPL/XML
Channels
3
Type
Transmit, 1:1 to 2:1 transformation ratio
Signals
Ref(+), Ref(-), Sin(+), Sin(-), Cos(+), Cos(-)
Resolution
14 bits (equivalent to a 4096 line quadrature encoder)
Reference Frequency
8 kHz
Reference Voltage
2.8 Vrms, auto-adjustable by drive for proper feedback levels.
Reference Max Current
100 mA
Max RPM
20,000
Function
Incremental or analog encoder or resolver required for sinusoidal commutation
and position or velocity modes of operation.
XE2/XP2/XM2
Channels
6
Type
Transmit, 1:1 to 2:1 transformation ratio
Signals
Ref(+), Ref(-), Sin(+), Sin(-), Cos(+), Cos(-) for each axis
Resolution
14 bits (equivalent to a 4096 line quadrature encoder)
Reference Frequency
8 kHz
Reference Voltage
2.8 Vrms, auto-adjustable by drive for proper feedback levels.
Reference Max Current
100 mA per axis
Max RPM
20,000
Function
Incremental or analog encoder or resolver required for sinusoidal commutation
and position or velocity modes of operation.
800-1819 and 800-1887
Contact Copley Controls for details.