Accelnet & Stepnet Plus Panels User Guide
16-01339 Rev 07
5.10 N
ETWORK
P
ORTS
E
THER
CAT:
BEL,
BE2,
TEL,
TE2
BEL, BPL, TEL,
BE2, BP2, TE2, TP2
M
ATING
C
ONNECTOR
Dual RJ-45 sockets accept standard Ethernet cables and are categorized as 100BASE-TX (100 Mb/sec) ports.
Cat 5 or Cat 5e (or higher) cables should be used. The IN port connects to a master, or to the OUT port of a
device that is ‘upstream’ between the
Plus Panels
and the master. The OUT port connects to ‘downstream’
nodes. If a
Plus Panel
drive is the last node on a network, only the IN port is used. No terminator is required
on the OUT port.
P
IN
D
ESCRIPTION
*
Pin
Signal
Function
1
TX+
Transmit data +
2
TX-
Transmit data -
3
RX+
Receive data +
4
-
5
-
6
RX-
Receive data -
7
-
8
-
*Table applies to both EtherCAT connectors
E
THER
CAT
B
US
W
IRING
D
IAGRAM
Drive
Jx
TX +
TX
-
RX +
EtherCAT Network ("In")
Jx-1
Jx-2
Jx-4
Jx-3
Jx-5
Jx-6
Jx-7
Jx-8
Jx-1
Jx-2
Jx-4
Jx-3
Jx-5
Jx-6
Jx-7
Jx-8
Opto-isolation
RX -
TX +
TX
-
RX +
RX -
EtherCAT Network ("Out")
Opto-isolation