Accelnet & Stepnet Plus Panels User Guide
16-01339 Rev 07
TE2/TP2
Size
6.78 x 4.69 x 1.74 in [172 x 119 x 44.1 mm] without heatsink
6.78 x 4.69 x 3.14 in [172 x 119 x 79.8 mm] with heatsink
Weight
Driver
Heat Sink
Heatsink
1.5 lb [0.68 kg]
1.25 lb [0.57 kg]
2.75 lb [1.25 kg]
Ambient Temperature
Storage
Operating
-40 to +85 C [-40 to +185 F]
0 to +45°C [+32 to +113 F]
Humidity
0% to 95%, non-condensing
Vibration
2
g
peak, 10~500 Hz (sine), IEC60068-2-6
Shock
10
g
, 10 ms, half-sine pulse, IEC60068-2-27
Contaminants
Pollution degree 2
Ingress Protection
IP20
Environment
IEC68-2: 1990
Cover Material
Meets U.L. Spec 94 V-0 Flammability Rating
Cooling
Heat sink and/or forced air cooling required for continuous power output
4.19 A
GENCY
S
TANDARDS
&
C
ONFORMANCE
•
Approvals
UL and cUL recognized component to UL 61800-5-1 (file no. E168959)
TÜV SÜD Functional Safety to IEC 61508 and ISO 13849-2
•
Functional Safety
IEC 61508-1, IEC 61508-2, EN(ISO) 13849-1, EN(ISO) 13849-2, IEC 61800-5-2:2016
(see the
Accelnet & Stepnet Plus Panels STO Manual
for further details)
•
Electrical Safety
Directive 2014/35/EU Low Voltage: IEC 61800-5-1:2007+AMD1:2016 CSV
UL 61800-5-1
•
EMC
Directive 2014/30/EU EMC: IEC 61800-3:2017
•
Hazardous Substances
Directive 2011/65/EU (RoHS Directive)