Accelnet & Stepnet Plus Panels User Guide
16-01339 Rev 07
DC Input
Power (cont’d)
S
INGLE
-A
XIS
S
TEPPER
M
ODEL
:
TEL
Model
TEL-090-07
TEL-090-10
Unit
DC +HV Voltage***
+14 to +90 (
transformer-isolated
from AC mains
)
Vdc
Peak +HV Current
7
10
Adc
Peak Current Time
1
Sec
ContHV Current
5
10
Adc
AuxHV Supply Voltage***
+14 to +90 (
transformer-isolated
from AC mains
)
Vdc
AuxHV Supply Current
500 mA maximum
Adc**
*The HV current is dependent on the input voltage and motor load and
operating conditions. The MHV currents shown above occur when the
drive is operating from the maximum input voltage and is producing the rated
continuous output current at the maximum output voltage.
**Logic supply current draw depends on the number of encoders connected to
the drive. The maximum current draw given assumes that the e5V
output is loaded to 500mA.
*** Supply Short Circuit Current Rating (SCCR) must be 5k Arms maximum
D
UAL
-A
XIS
S
TEPPER
M
ODELS
:
TE2,
TP2
Model
TE2-090-07
TP2-090-07
TE2-090-10
TP2-090-10
Unit
DC +HV Voltage***
+14 to +90 (
transformer-isolated
from AC mains
)
Vdc
Peak +HV Current
14
20
Adc
Peak Current Time
1
Sec
ContHV Current
10
20
Adc
AuxHV Supply Voltage***
+14 to +90 (
transformer-isolated
from AC mains
)
Vdc
AuxHV Supply Current
500 mA maximum
Adc**
*The HV current is dependent on the input voltage and motor load and
operating conditions. The MHV currents shown above occur when the
drive is operating from the maximum input voltage and is producing the rated
continuous output current at the maximum output voltage.
**Logic supply current draw depends on the number of encoders connected to
the drive. The maximum current draw given assumes that the two e5V
outputs are each loaded to 500mA.
*** Supply Short Circuit Current Rating (SCCR) must be 5k Arms maximum