5-28
Using Copley
Motion Explorer
Status Outputs
On the
Amplifier Status Now!
screen, there is a
segment (Figure 5-17) that lets you program the Status
Outputs lines from the Amplifier to be read on
pendant.
You can program the pendant indicators
STAT-0
and
STAT-1
to indicate whether a motion profile is active or a
fault has occurred. Select the
Status Output
button to
open the
Status Output
screen. Check the appropriate
status box,
True/False
button and
On (Hi/LO)
option.
Figure 5-17 Status Outputs Screen Segment
STAT-0
and
STAT-1
have mask and sense bytes (Hex).
Mask data is sent to the amplifier. Sense data is read
from the amplifier.