Figure 22
RED CONNECTOR
(POWER IN)
BLACK CONNECTOR
(RS485 CONTROL IN)
VIDEO OUT
RED LINE (AC24V IN)
BLACK LINE (AC24V IN)
ORANGE LINE (RS485+)
YELLOW LINE(RS485-)
RED1:
ORANGE2:
YELLOW3:
GREEN4:
BLACK5:
WHITE6:
BLUE7:
PINK8:
The synthetical wires as follows
(
Figure22
)
,
Orange
、
Yellow is RS485-
;
While you are using AC24V power line
,
the red and
black is the input side of the power
;
BNC connector is the video-out side
(
Take carefully while you connect these wires
).
The description of Alarm out-line
(
Figure23
)
.
The o description of Alarm out-line.
According the fig of D3 to connection. As show of figure 24-1, when dome
identify the alarm signal, that will set according the program immediately,
then startup camera, switching the image of alarm field to main monitor.
Surveillance the alarm preset, then record it in time. Fig24-2 is connection
of alarm control.
II. The outlines description
7
Figure 23
1
2
3
!
Input of alarm: Input signal of switch type, any other input signal will
damage dome. When multi-channel with alarm signal, dome will
respond one by one, the removed time is two sec.
!
Once the dome have alarm input, dome will not respond
“
scanning
”
、
“
patrol
”
、“
remember tracking
”
etc function.
The outlines
description
ALARM-1 IN
ALARM-2 IN
ALARM-3 IN
ALARM-4 IN
ALM IN COM
ALARM OUT COM
ALARM NO OUT
ALARM NC OUT