Cooper Lighting Streetworks SA6001-SA6002 Installation Instructions Download Page 1

These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible
contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please
contact your nearest representative.

ARM INSTALLATION

Bishop Arm (SA6001-SA6002, SA6050-SA6051, SA6101-SA6102
& SA6150-SA6151) 
See Figure 1.
1.

Secure arm mount flush with wall using 3/8” hardware supplied 
by others.

2

.

Remove wireway cover screws and wireway cover.

3

.

Mount arm to arm mount positioning service leads in wireway. 
Insert and tighten four screws to 80 in/lbs.

4.

Pull fixture leads through arm.

5.

Align locating pin and socket when raising fixture to arm. 
See Figure 2.

6.

Insert and tighten 4 fixture screws with Teflon washers, provided 
in polybag, to 80 in/lbs.

7.

Connect fixture leads to service leads in wireway.

8.

Resecure wireway cover with wireway cover screws tightened to 
50 in/lbs.

Traditional Arm (SA6003-SA6004, SA6052-SA6053, SA6103-
SA6104 & SA6152-SA6153)
See Figure 3.
1.

Secure arm mount flush with wall using 3/8” hardware supplied 
by others.

2.

Remove wireway cover screw and wireway cover.

3.

Mount arm to arm mount positioning service leads in wireway. 
Insert and tighten set screw to 80 in/lbs.

4.

Pull fixture leads through arm.

5.

Align locating pin and socket when raising fixture to arm. 
See Figure 2.

6.

Insert and tighten 4 fixture screws with Teflon washers, provided 
in polybag, to 80 in/lbs.

7.

Connect fixture leads to service leads in wireway.

8.

Resecure wireway cover with wireway cover screw tightened to 
50 in/lbs.

Customer First Center  •  1121 Hwy 74 South  •  Peachtree City, GA  30269

IMI-658    ADW051684

Epic/Wall Mounted

Fixtures

Sheet 1 of 4

10/18/05         IMI-658

INSTALLATION INSTRUCTIONS

IMPORTANT: 

Read carefully before installing fixture. Retain for future reference.

General:

Upon receipt of fixture thoroughly inspect for any

freight damage, which should be brought to the attention of
the delivery carrier. Compare the catalog description listed
on the packing slip with the fixture label on the housing to
assure you have received the correct merchandise.

Safety:

This fixture must be wired in accordance with 

the national electrical code and applicable local codes 
and ordinance. Proper grounding is required to insure 
personal safety. Carefully observe grounding procedure
under installation section. All work should be done by a 
qualified electrician.

TM

WARNING: 

Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing
or servicing.

Fixture Screws (4)

Fig. 1

Bishop Arm

Teflon Washer (4)

(4) 3/8-16 x 1-1/4
Button Head Cap
Screws

Backplate Med
Bishop Wall

Wireway Cover

(4) 3/8" Lag Bolts
(supplied by others)

Wireway Cover
Srews (2)

Aligning Pin

Aligning Socket

Fig. 2a

Modern Top

Reviews: