background image

1

  

PORTFOLIO

®

Installation Instructions for HD7500QT4 and HD7250QT4
Commercial Recessed Housing

CAUTION: 

To avoid possible electrical shock, be sure that power supply is turned
off before installing or servicing this fixture.

Note:

This fixture should be supported by main runners or other structure that
is capable of supporting fixture weight of 17lbs.

Step 1

To Install Fixture:  Using standard bar hangers, C-Channels (available
through Portfolio or furnished by others), ¾” and 1-1/2” lathing or ½”
conduit (all supplied by others), insert thought the universal hanger
brackets and secure the mounting bars or channels to the ceiling
structure so that the edge of the die cast mounting frame is flush with
the finished ceiling.

Step 2 

To Install Upper Reflector:  Cut plastic tie wrap securing heat sink to
bracket. Install quartz mini-can frosted lamp. 

WARNING: DO NOT

handle quartz lamps with bare hands. Grease from fingerprints
may cause premature end of life or shattering of lamp.

 Install heat

sink to upper reflector assembly carefully guiding lamp into reflector
opening (Fig 1).  Rotate heat sink until flanges are seated under
retention springs. Insert completed assembly through housing opening
and into moveable bracket until seated securely (Fig 2).

Step 3 

To Install Lower Trim:  Attach trim safety tether to mounting bracket  via
clip. Trim is held in place with torsion springs that pass through slots in
mounting bracket.

Housing

Heat Sink and
Lamp Assembly

Top Accessory Cover

Upper Reflector
Assembly

Hanger Bracket

Junction Box

Plaster Frame

Junction Box
Cover

Lower Reflector
Assembly

FIG 1

Reviews: