background image

NOTES: For complete product data, refer to the Neo-Ray Specification Binder. Specifications and dimensions subject to change without notice. Products may be
modified for use in international markets. Please contact your Cooper Lighting Sales Representative for availability and ordering information.

738

COOPER LIGHTING

SHELL II

201-IW

D I R E C T- I N D I R E C T

W

ALL

7-7/8" [200mm] 

2-1/2" 

[63mm] 

ORDERING INFORMATION:

Sample number: 201IW-SP-1T5HO-1C-120-SU-WA-24

Series

201IW

=Shell II Wall Mount

Optics Up

S

=Specular

Optics Down

P

=Perforated

Number of Lamps 

(not included) 

1

=1 Lamp

2

=2 Lamps (T5 only)

Lamp Type

T5HO

=54W HO (4’ Unit)

T8

=32W (4’ Unit) (1 Lamp only)

Number of Circuits 

1

1

=1 Circuit

2

=2 Circuits (Side by Side)

Wiring

C

=Standard Circuit

E

=Emergency/Night Light

D

=Dimming

B

=Battery Pack

Voltage 

1

1

=120V

2

=277V

3

=347V

U

=Universal

SU-WA

=Surface/Wall Mount

Run Length

Individual or continuous runs will be configured with 4’ and 8’
sections only (see sample catalog #)

1 Due to various constraints, some options may not be combined with others. 

Construction

Housing is one-piece, die-formed, cold rolled steel,
forming a 7-7/8” x 2-3/4” architectural profile.
Perforated sections are 33% with staggered hole
pattern with white acrylic overlay. Standard 4’-0”
and 8’-0” luminaire lengths combine for continuous
runs.

End Caps

Standard end caps are precision die-cast aluminum
mechanically attached without exposed fasteners.

Reflectors

Reflector is die-formed, semi- specular anodized
aluminum.

Electrical

Luminaires are prewired with quick wire connectors
and use UL list Class P, T5HO or T8 electronic
ballasts. Power factor of 97% with less than 10%
THD. Fixtures and electrical components certified to
UL and CUL standards.      

Finish

Luminaire housings are standard white using
electrostatically applied acrylic powder coat paint.

Mounting

Fixture mounts directly to existing structure over a
2” x 4” standard electrical box 

mounted

horizontally

in the wall.

• Semi – indirect light

distribution.

• T5 and T8 lamping options.

• Die formed steel perforated

housings.

• Modular housing lengths –

4’and  8’ for individual or
continuous runs.

• Precision die cast end caps.

• Adjustable mounting block

for accurate leveling.

48"[1219mm

]*

96"[2438mm]*

*Dimensions do not include end caps.

S T A N D A R D   L U M I N A I R E   L E N G T H S *

END CAP

1-1/4"
[38mm]

2-1/2"
[64mm]

7-1/8" [181mm]

= Slim Line Ballast only.

S

S

T8 = 1 Lamp

T5 = 1 or 2 Lamp

NEO-RAY