•  Do not use this apparatus near water.
•  Clean only with a dry cloth.
•  Do not block any ventilation openings. Install in accordance with the manufacturer’s 

  instructions.
•  Do not install near any heat sources such as radiators, heat registers, stoves or other 

  apparatus (including amplifiers) that produce heat.
•  Only use attachments/accessories specified by the manufacturer.
•  Disassembly of your fixture will void the warranty.
•  Your fixture is prewired and preassembled for easy installation.
•  MINIMUM 90° C SUPPLY CONDUCTORS.
•  If lens is replaced, use only tempered safety glass of equal thickness per UL requirements.
•  This device complies with Part 15 of the FCC Rules. Operation is subject to the following 

  two conditions: (1) This device may not cause harmful interference, and (2) this device must 

  accept any interference received, including interference that may cause undesired operation.

  Under Part 15   of the FCC Rules, any changes or modifications to the motion detector

  described in this instruction sheet that are not expressly approved by Cooper Lighting, LLC 

  could void the user’s authority to operate the equipment.

NOTE:

 This equipment has been tested and found to comply with the limits for a Class B 

digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide 

reasonable protection against harmful interference in a residential installation. This 

equipment generates, uses and can radiate radio frequency energy and if not installed 

and used in accordance with the instructions, may cause harmful interference to radio 

communications. However, there is no guarantee that interference will not occur in a particular 

installation. If this equipment does cause harmful interference to radio or television reception, 

which can be determined by turning the equipment off and on, the user is encouraged to try to 

correct the interference by one or more of the following measures:

  -  Reorient or relocate the receiving antenna.

  -  Increase the separation between the equipment and receiver.

  -  Connect the equipment into an outlet on a circuit different from that to which the receiver 

    is connected.

  -  Consult the dealer or an experienced radio/TV technician for help.

WARNING: FCC Regulations state that any unauthorized changes or modifications 

to this equipment not expressly approved by the manufacturer could void the user’s 

authorization to operate this equipment.
SAVE THESE INSTRUCTIONS.

FOR BEST RESULTS

•  Install the motion sensor/transmitter 8-12 feet 

  above the ground. (Motion sensor is less sensitive 

  above 12 feet.)
•  Locate motion sensor so motion moves across 

  detection zone (Fig. 1).
•  Locate sensor away from heat producing sources to

  prevent false triggering. Also be very careful not to 

  include objects such as windows, white walls and

  water in the detection zone.

PACKAGING CONTENTS/CONTENIDO DEL PAQUETE

ITEMS REQUIRED

 

(Purchase separately)

•  Phillips screwdriver
•  Flathead screwdriver
•  Hammer
•  Outdoor weatherproof silicone caulking

HOW IT WORKS

Your motion activated floodlight senses heat images from 

objects such as people, large animals and automobile engines. 

When motion is detected, the lights will automatically turn 

on. Once motion has stopped, the lights will turn off after a 

preselected time delay. Your motion activated floodlight may 

also be used as a standard floodlight.

WARNINGS AND CAUTIONS

•  Follow all instructions.
•  For outdoor use only.
•  cULus LISTED for wet locations.
•  Connect fixture to a 120 volt, 60 Hz power source. Any other connection voids the warranty.
•  Fixture must be mounted to a grounded recessed junction box marked for use in wet locations.
•  Suitable for wall mount or eave mount only. NOT suitable for ground mount installation.
•  Do not allow sensor head to touch light housing – maintain at least 1 inch space between 

  fixture and sensor.
•  Keep away from flammable objects. Do not position fixture within two inches

  of any combustible materials.
•  Do not position lamp housing within two inches of house.
•  Bulb gets HOT quickly! 
•  The bulb and fixture get extremely hot during use. Disconnect power and allow fixture to 

  cool before changing bulb or handling fixture.
•  Fixture should be installed by persons with experience in household wiring or by a qualified  

  electrician. The electrical system, and the method of electrically connecting the fixture to it,  

  must be in accordance with the National Electrical Code and local building codes.
•  Always replace bulb with the same wattage or lower wattage than included. Installing a 

  bulb of a higher wattage could create a fire hazard. Use of a higher wattage bulb will void 

  the warranty. (Maximum 150 watt halogen bulb.) To meet ENERGY STAR

®

 requirements, 

  maximum lamp wattage cannot exceed 250 watts.
•  Never touch the bulb with your bare hands, as oil from your skin can cause premature 

  failure. Always handle bulb with gloves or a soft cloth.
•  For proper operation and protection against damage, the motion 

  sensor head adjustment knobs must be facing the ground.
•  For maximum bulb life, position fixture so the quartz halogen 

  bulb remains within 4 degrees of horizontal.

MS80 (Bronze)

MS80W (White)

A.

  Motion detector 

  and light fixture
  Detector de 

  movimiento y 

  artefacto de luz

 

ENGLISH

Up to

70 feet

180 degrees

B.

  150 watt quartz halogen bulb 

  (preinstalled)
  Foco halógeno de cuarzo de 

  150 vatios (preinstalado)

D.

  (2) #6 and (2) #8 mounting screws 

   (use the size that fits your junction box)
   (2) Tornillos #6 y (2) tornillos #8 de montaje

   (utilice el tamaño que mejor se adecue a 

   su caja de conexión)

C.

  Coverplate gasket

  Junta de la placa 

  de cubierta

E.

  (3) Wire nuts

   (3) Tuercas 

   para alambre

Fig. 1

Summary of Contents for MS80

Page 1: ...way from heat producing sources to prevent false triggering Also be very careful not to include objects such as windows white walls and water in the detection zone PACKAGING CONTENTS CONTENIDO DEL PAQUETE ITEMS REQUIRED Purchase separately Phillips screwdriver Flathead screwdriver Hammer Outdoor weatherproof silicone caulking HOW IT WORKS Your motion activated floodlight senses heat images from ob...

Page 2: ...e premature failure 4 To install bulb position bulb into spring loaded socket and push bulb toward socket until it depresses Position other end of bulb into stationary socket opposite socket Be sure each end of bulb is securely positioned against the socket Fig 2 Octagonal Round Fixture ground House ground Black fixture wire White fixture wire White house power wire Black house power wire E E E A ...

Page 3: ...strictly prohibited For assistance call 1 800 334 6871 or e mail us at ConsumerProducts cooperlighting com Printed in China ARTÍCULOS NECESARIOS se compran por separado Destornillador en cruz Phillips Destornillador de cabeza plana Martillo Calafateo de silicona resistente a la intemperie CÓMO FUNCIONA La lámpara de alta intensidad activada por movimiento detecta imágenes térmicas de objetos tales...

Page 4: ...inarse apagándolo y encendiéndolo se recomienda al usuario que trate de corregir la interferencia por medio de una o más de las siguientes medidas Reoriente o cambie de lugar la antena receptora Aumente la separación entre el equipo y el receptor Conecte el equipo en un tomacorriente que esté en un circuito difer ente de aquél al que se conecta el receptor Consulte a su proveedor o a un técnico de...

Page 5: ...Automático activado por movimiento Las luces deberán encenderse con el movimiento únicamente durante la noche y apagarse después de 4 12 minutos que cese el movimiento AUTO 4 MIN o AUTO 12 MIN Mantenga la alimentación del portalámparas activada Ajuste Amanecer Atardecer activado sólo durante la noche Las luces deben permanecer encendidas desde el atardecer hasta el amanecer y luego restituirse a l...