Cooper Lighting Metalux GCAFA Series Specification Sheet Download Page 1

404

COOPER LIGHTING

RECESSED AIR SUPPL

Y

GCAFA 

SERIES

1 '   x   4 ' ,   2 '   x   2 ' ,   2 '   x   4 '  
o r   2 0 "   x   4 8 "   Tr o f f e r  
1 ,   2 ,   3   o r   4   L a m p                            

S P E C I F I C AT I O N   R E C E S S E D

A I R   S U P P LY   T R O F F E R  

• Equipped with energy

saving ballasts/complies
with federal energy
efficiency standards

• Floating extruded

aluminum door/black reveal

• Self locking, spring loaded

Cam latch/T hinge

• Die embossed para-

contoured housing 

(6)

• Deep “V” raceway/ballast

cover

(7)

• End plates secured with

interlocking tabs and
screws

• Four auxiliary fixture end

suspension points
provided

• End plate grid-lock 

feature

(9) (12)

• Efficient air handling

options

• For information on flanged

fixture, including ceiling
opening size, see Technical
Section.

• UL/CUL Listed. Suitable for

damp locations.

D I M E N S I O N S

D E S C R I P T I O N

The GCAFA Series features a
nominal 4-1/2" deep para-contoured
fixture housing, high reflectivity and
optimum lamp to lens spacing. The
finish provides high reflectance. The
Series produces total uniformity of
light in the luminous area and is
compatible with all of today’s
popular ceiling systems. The GCAFA
Series is an excellent choice for
commercial office spaces, schools,
hospitals or retail merchandising
areas.

B

A

NOMINAL SIZE

A

B

1' x 4'

11-3/4" (298mm)

5-5/8" (143mm)

2' x 2'

23-3/4" (603mm)

4-5/8" (117mm)

2' x 4'

23-3/4" (603mm)

4-5/8" (117mm)

20" x 48"

19-3/4" (502mm)

4-5/8" (117mm)

O R D E R I N G   I N F O R M AT I O N  

S A M P L E   N U M B E R :   2 G C A F A - 2 3 2 A - 1 2 0 V - E B 8 1 - U

Number of Lamps

(2)

1, 2, 3

or

4

lamps

(Not Included)

Wattage (Length)
U6

=40W T12 (24")

U6T8

=32W T8 (24")

U15/8

=31W T8 (24")

BX40

=40W Biax (24")

17

=17W T8 (24")

20

=20W T12 (24")

40

=40W T12 (48")

32

=32W T8 (48")

Shielding
A

=#12 PatternAcrylic

(See Lens and Louver Tables for
additional shielding options)

2'

Width

Series
C

=Specification

Deep Troffer

Trim Type
G

=Grid/Lay-in –

Standard

G

=Concealed T

G

=Slot Grid

(1)

F

=Flange Trim

MZ

=Modular Trim

Doorframes
FA

=Flat White Extruded

Aluminum Door

RA

=3/8" Regressed White

Extruded Aluminum Door

FAN

=Flat Natural Extruded

Aluminum Door

RAN

=3/8" Regressed Natural

Extruded Aluminum Door

FAB

=Flat Black Extruded

Aluminum Door

RAB

=3/8" Regressed Black

Extruded Aluminum Door

A

=For Air Handling Floating

Door, Black Reveal

B

=For Non-Air Handling

Floating Door, Black Reveal

V

=Directional Air Vane For Use

With Air Handling Fixture Only

Blank

=No Vane

2048

=20" Width

x 48" Length

Voltage

(3)

120V

=120 Volt

277V

=277 Volt

347V

=347 Volt

UNV

=Universal Voltage 120-277

(4)

Starting Type
LTS

=Low Trigger Start (20 Watt)

(120V only)

HTS

=High Trigger Start (20 Watt)

Options
GL

=Single Element Fuse

GM

=Double Element Fuse

WTR

=White Reveal

Lamps

- for lamps installed, see lamp options table

Flex

- for flex installed, see flex ordering table

Emergency

- for EM installed, see EM options table

Ballast Type

(3)

Blank

=Standard Magnetic Ballast (Biax

& 20W)

LEOC8

=T8 Magnetic Energy Saving

LE3

=T12 Magnetic Energy Saving

ER8

= T8 Electronic Program Rapid Start. 

Total Harmonic Distortion < 10%

EB8

= T8 Electronic Instant Start. Total 

Harmonic Distortion < 20%

EB8 /PLUS

= T8 Electronic Instant Start. 

High Ballast Factor >1.13. 
Total Harmonic Distortion 
< 20%

TEB8

=T8 Electronic Instant Start. Total 

Harmonic Distortion < 10%

EB5

= T5 Biax Electronic Instant Start. 

Total Harmonic Distortion < 20%

TEB5

=T5 Biax Electronic Instant Start. 

Total Harmonic Distortion < 10%

EB2

=T12 Electronic Rapid Start. 

DLS

=Digital Lighting System Dimming

(For complete details on generic or to specify
manufacturer’s ballast see pg. 469)

No. of Ballast
1, 2 or 3

No. of Ballast
1, 2 or 3

No. of Ballast
1, 2 or 3

No. of Ballast
1, 2 or 3

No. of Ballast
1, 2 or 3

No. of 
Ballast
1, 2 or 3

No. of Ballast
1 or 2

Options

(See Options
Section)

Packaging
U

=Unit Pack

PAL

=Job Pack,

out of carton

PALC

=Job Pack,

in carton

COOPER LIGHTING - METALUX

®

NOTES:

(1)

An EQ Grid Clip is recommended for all 9/16" ceiling systems. 

(2)

Standard off-center ballast compartment on 3-lamp fixtures. 

(3)

Products also available in non-

US voltages and frequencies for international markets. 

(4)

Not available when specifying emergencies, voltage must be specific.

For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting
Representative for availability and ordering information.

Reviews: