background image

P

ARALUX IV

390

COOPER LIGHTING

• Equipped with energy

saving ballasts/complies
with federal energy
efficiency standards

• Computer designed,

precision cell louver
technology

• Field convertible feature

• Self-locking spring loaded

cam latches/T hinges

• Four auxiliary fixture end

suspension points 

• Interlocking tabs and

screws secure end plates

• End plate grid-lock feature

(1)

• Efficient air handling options

• Hard metric configurations

are available

• Floating louver/black reveal

• For information on flanged

fixture, including ceiling
opening size, see Technical
Section.

• UL/CUL Listed. Suitable for

damp locations.

2PGAX

SERIES

1 '   x   2 ' ,   1 '   x   4 ' ,   2 '   x   2 ' ,  
2 '   x   4 ' ,   2 0 "   x   2 4 " ,  
2 0 "   x   4 8 "   P a r a b o l i c

1 ,   2 ,   3   o r   4   L a m p
P a r a b o l i c   L o u v e r

PA R A L U X   I V  

R E C E S S E D   A I R              

S U P P LY   T R O F F E R

D I M E N S I O N S

D E S C R I P T I O N

The Paralux IV series features
recessed aesthetics and the latest in
energy efficient technology.
The luminaire incorporates a 4"
precision cell louver into a nominal
6-1/2" deep para-contoured fixture
housing. This combination creates a
high comfort parabolic optical
assembly for optimum performance.
The Paralux IV series offers balanced
illumination with reduced glare,
increased VCP’s and excellent
shielding. The series is compatible
with all of today’s popular ceiling
systems. The Paralux IV series is an
excellent choice for commercial
office spaces, schools, hospitals or
retail merchandising areas.

NOMINAL SIZE

A

B

1' x 2'

11-3/4" (298mm)

7-5/8" (194mm)

1' x 4'

11-3/4" (298mm)

7-5/8" (194mm)

2' x 2'

23-3/4" (603mm)

6-5/8" (168mm)

2' x 4'

23-3/4" (603mm)

6-5/8" (168mm)

20" x 24"

19-3/4" (502mm)

6-5/8" (168mm)

20" x 48"

19-3/4" (502mm)

6-5/8" (168mm)

Housing Louver 

Cell

Number

Size

Configuration*

of Cells

1' x 2'

13, 14, 23, 24

3, 4, 6, 8

1' x 4'

16, 18, 19, 26, 28, 29

6, 8, 9, 12, 16, 18

2' x 2'

22, 23, 24, 33, 34, 44

4, 6, 8, 9, 12, 16

20" x 24"

23, 24, 33, 34

6, 8, 9, 12

20" x 48"

26, 28, 29, 36, 38, 39, 46, 48, 49

12, 16, 18, 18, 24, 27, 24, 32, 36

2' x 4'

26, 28, 29, 36, 38, 46, 48, 49

12, 16, 18, 18, 24, 24, 32, 36

*Example: 36= 3 rows of 6 (18 cells)

P R O D U C T   I N F O R M AT I O N   F O R   PA R A L U X   I V

O R D E R I N G   I N F O R M AT I O N

S A M P L E   N U M B E R :   2 P G A X - 3 3 2 S 3 6 I - 1 2 0 V - E B 8 1 - U

Options

(See Options
Section)

Number
of Lamps 

(4)

1, 2, 3 

or

4

lamps

(Not included)

Wattage (Length)
U6T8

=31W T8 (24")

17

=17W T8 (24")

U15/8

=31W T8 (24")

BX40

=40W Biax (24")

32

=32W T8 (48")

2048=

20" Width 

x 48" Length

2024=

20" Width

x 24" Length

Voltage

(5)

UNV

=Universal

Voltage 120-277

(6)

347V

=347 Volt

Louver Color
S

=Silver

W

=White

Cell Configuration*

(See below for Louver Options)

Louver Finish
H

=Semi-Specular/Haze (Gold only)

I

=Semi-Specular/Haze (Low Iridescent) Standard

(Silver Only)

MI

=Specular/Mirrored (Low Iridescent) (Silver Only)

P

=Painted (White only)

HR

=Heat

Removal

(1)

HRDO

=Heat

Removal
Damper Open

HRDC

=Heat

Removal
Damper Closed

P

=Paralux Louver

Width
2'

=2' width

Blank

=1' width 

or 20" width

Trim Type
G

=Grid/Lay-in (Standard)

G

or

T

=Concealed T

G

or

T

=Slot Grid

(2)

F

=Flange Trim

MZ

=Modular Trim

Convertible Fixture

Standard G (Grid)

Type-Fixtures can be field converted to 
T-option or vice-versa.

(3)

Fixture also

adaptable with flanged or modular trims.

AX

=Air Supply Floating Louver

X

=Blank Side/Floating Louver -

Non-Air Supply (Omit A)

AVX

=Air Supply Floating Louver

with Directional Air Vane (Add V)

HM

=Hard

Metric

Options
GL

=Single

Element Fuse

GM

=Double

Element Fuse

WTR

=White

Reveal

Lamps

- for lamps

installed, see lamp
options table

Flex

- for flex

installed, see flex
ordering table

Emergency

- for

EM installed, see
EM options table

Ballast Type

(5)

Blank

=Standard

Magnetic Ballast (Biax & 20W)

LE3

=T12 Magnetic Energy Saving

EB8

= T8 Electronic Instant Start. 

Total Harmonic  Distortion < 10%

EB8 /PLUS

= T8 Electronic Instant Start. 

High Ballast Factor >1.13. Total 
Harmonic  Distortion < 20%

ER8

= T8 Electronic Program Rapid Start. 

Total Harmonic Distortion < 10%

EB5

= T5 Biax Electronic Instant Start. 

Total Harmonic Distortion < 20%

TEB5

=T5 Biax Electronic Instant Start. 

Total Harmonic Distortion < 10%

EB2

=T12 Electronic Rapid Start. 

DLS

=Digital Lighting System Dimming

(For complete details on generic or to specify
manufacturer’s ballast see pg. 469)

No. of Ballast
1, 2 or 3

No. of 
Ballast
1, 2 or 3

No. of Ballast
1, 2 or 3

No. of Ballast
1, 2 or 3

No. of Ballast
1, 2 or 3

No. of Ballast
1 or 2

NOTES:

(1)

Integral end plate grid lock feature not available in heat removal. 

(2)

An EQ Grid Clip is recommended for all 9/16" ceiling systems. 

(3)

Convertibility applies to

housing only, appropriate shielding media assemblies must be utilized. 

(4)

Standard off-center ballast on 3-lamp fixtures. 

(5)

Products also available in non-US voltages and

frequencies for international markets. 

(6)

Not available when specifying emergencies, voltage must be specific.

For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting
Representative for availability and ordering information.

COOPER LIGHTING - METALUX

®

Packaging
U

=Unit Pack

PAL

=Job Pack,

out of carton

PALC

=Job Pack,

in carton

Reviews: