1. 

Using 3/16” Allen Wrench, remove wiring 
compartment cover.

2

.  Feed supply leads through fitter and out wireway 

compartment opening. Slide fitter over tenon.

3.

Tighten (4) set screws to 225 in. lbs. using 3/16” 
Allen Wrench.

4

.  Splice supply leads to fixture leads making sure to 

ground the fixture in a manner that complies with 
National Electric Code and applicable local codes. 
DO NOT USE POLE AS GROUND. Push wires in to 
wiring compartment and reinstall cover and gasket.

Customer First Center  •  1121 Hwy 74 South  •  Peachtree City, GA  30269 

IMI-563    A

VU

032732

VFM Vision Flood-Medium

Fitter Mount

Sheet 1 of 1

10/09/03

IMI-563

INSTALLATION INSTRUCTIONS

IMPORTANT: 

Read carefully before installing fixture. Retain for future reference.

General:

Upon receipt of fixture thoroughly inspect for any

freight damage, which should be brought to the attention of
the delivery carrier. Compare the catalog description listed
on the packing slip with the fixture label on the housing to
assure you have received the correct merchandise.

Safety:

This fixture must be wired in accordance with 

the national electrical code and applicable local codes 
and ordinance. Proper grounding is required to insure 
personal safety. Carefully observe grounding procedure
under installation section. All work should be done by a 
qualified electrician.

TM

WARNING: 

Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing
or servicing.

GASKET

FITTER

FIXTURE

LEADS

1/4-20 BOLT

SUPPLY LEADS

WIRING
COMPARTM
COVER

2-3/8" OD TENON

ALLEN WRENCH

SET SCREWS

5. 

Loosen fitter bolt using 3/8” Allen Wrench and 
adjust fixture to desired aiming angle. Retighten bolt 
to a minimum of 250 in. lbs.

6

.  Open door using 3/16” Allen Wrench and install 

lamp.

REFLECTOR AND LENS CLEANING
1. 

Open fixture door.

2. 

Dust reflector with soft, clean dry cloth.

3. 

Clean lens with any non-abrasive glass cleaning 

solution and rinse with clean water.

4. 

Wipe lens dry with clean, dry cloth.

NOTE: A regular maintenance schedule should be 
followed to retain optimal light output and reduce 
heat retention.
DO NOT use alkaline or acid cleaners on reflector 
surfaces.

ALLEN WRENCH

FITTER BOLT

TOOLS REQUIRED:  3/16” Allen Wrench

3/8” Allen Wrench 