background image

FAIL-SAFE

®

TRANSIT

• Fiberglass housing is

reinforced polyester and
self extinguishing (ASTM-
D635-74) plastic; top has
five embossments (2' unit);
watertite hubs for 1/2"
conduit entry. Polyurethane
gasketing

•  Ballasts are CBM/ETL Class

"P" suitable to minus 20°F.

•  Three shielding choices:

DR–clear, low brightness
pattern acrylic with 15%
high impact additive; 
DR-100–clear, low
brightness pattern acrylic
with 100% high impact
additive; LEX, low
brightness pattern, high
impact LEXAN
polycarbonate

• Four sturdy cam latches 

(2’ unit), six (4’ unit), and
twelve (8’ unit) with
integral stainless steel
TORX

®

screws. Clamp

diffuser tightly for a
positive seal between
housing, gasketing and
diffuser.

D E S C R I P T I O N

The Fail-Safe VRVT2 Series
fluorescent luminaires
combine harsh environment
protection with the latest in
energy efficient technology.
Their Vaportite design is U.L.
listed and C.S.A. certified for
wet locations. Other features
include continuous seal
gasketing, reinforced
fiberglass housing, steel
mounting brackets, and end
hub entry (standard) or top
hub entry (optional.)

VRVT2

2 ' ,   4 ' ,   8 '   L O N G  

1   O R   2   L A M P

V A N D A L   R E S I S T A N T

L U M I N A I R E

A

B

C

D

VRVT2

5 7/8"

7"

6 5/8"

25 13/16" 

2'

(149mm)

(178mm)

(168mm)

(656mm)

VRVT2

5 7/8"

7"

6 5/8"

49 13/16"

4'

(149mm)

(178mm)

(168mm)

(1265mm)

8VRVT2

5 7/8"

7"

6 5/8"

97 13/16"

8'

(149mm)

(178mm)

(168mm)

(2484mm)

M O U N T I N G

A

D

C

B

D I M E N S I O N S

Tandem
8T

=8'

Length

Series
VRVT2

O R D E R I N G   I N F O R M AT I O N

S A M P L E   N U M B E R :   V R V T 2 - 2 3 2 D R - 1 2 0 V - E B 8 1 - W L - U

Number of
Lamps
1 or 2

Lamps

(Not included)

Wattage (Length)
20

=20W (24")

1

17

=17W T8 (24")

BX40

=40W Biax (24")

BX50

=50W Biax (24")

40

=40W (48")

32

=32W T8 (48")

48

=60W (48") SL

96

=110W (96") HO

96T8

=59W (96") SL)

Lens
DR

=Internal Prismatic Lens/15% DR High

Impact Additive (Standard)

DR-100

=100% High Impact Additive

LEX

=High Impact Clear Polycarbonate LEXAN

Lens/Low Brightness Pattern

Voltage

2

120

=120V

277

=277V

347

=347V

UNV

=

Universal
Voltage
120-277V

LTS

=Low

Trigger
Start (20
Watt)

HTS

=High

Trigger
Start (20
Watt)

HO

=High Output (800 MA)

Ballast Type 

2

Standard Magnetic
Ballast
Leave Blank

LE3

=

Energy Saving
Ballast

LEOC8

= Energy Saving

Ballast        
(T-8 Lamp
Only)

EB _ _

= Generic 

Electronic
Ballast

No. of 
Ballasts
1

or

2

Lamp Size
2

=T12

8

=T8

5

=T5

(For Specific Electronic
Ballast Specify Brand
and Catalog Number)

WL

=Wet

Label

Options
GL

=Internal Single

Element Fusing

GM

=Dual Element

Fusing

EL4

=Emergency

Lighting self-
contained.

EL8

=Emergency

Lighting self-
contained.

RIF1

=Radio

Interference
Suppressor

TH

2

=(2) Top

Watertite Hubs

3

TEH

2

=(2) Top & (2)

End Watertite Hubs
(All Watertite

3

Hubs

Have 1/2" Conduit
Entry)

TILW

=Tandem In-

Line Wiring Option

PI/CPI

=Plug-In

Option

RLS

=Rotor-Lock

Socket (T8 Lamps
Only)

DL

=Damp Location

Labeled

WL

=Wet Location

Labeled

DD

=Deep Diffuser

(Available On 4'
Fixtures. Deep
Housing
Standard On 8'
Fixtures)

N O T E :

For additional options, consult your Cooper Lighting Representative.  Specifications and Dimensions subject to change 

without notice.

1

Standard Ballast (Non-LE3). 

2

Contact Pre Sales Technical Support. 

3

Optional VT2 1/2" stem bushing available.

4

Ambient Thermal

Conditions: Operating Ambient Temperature    Limitations Are Applicable. Contact Sales Engineering for   Full“Operating Temperature
Range” of Specific Fixture.

COOPER LIGHTING

1509

Reviews: