Instruction Manual / Manuel d’instructions/ Instrucciones

PACKAGING CONTENTS /CONTENU DE L’EMBALLAGE/CONTENIDO DEL PAQUETE

communications. However, there is no guarantee that interference will not occur in a 
particular installation. If this equipment does cause harmful interference to radio or 
television reception, which can be determined by turning the equipment off an on, the 
user is encouraged to try to correct the interference by one or more of the following 
measures:

• 

Reorient or relocate the receiving antenna.

• 

Increase the separation between the equipment and receiver.

• 

Connect the equipment into an outlet on a circuit different from that to which  

  the receiver is connected.

• 

Consult the dealer or an experienced radio/TV technician for help. 

      

WARNING: FCC Regulations state that any unauthorized changes or modifications 

to this equipment not expressly approved by the manufacturer could void the user’s 

authorization to operate this equipment.
SAVE THESE INSTRUCTIONS.

MOUNTING AND WIRING YOUR FIXTURE

WARNING: Risk of electric shock. Disconnect 

power at fuse or circuit breaker before installing or 

servicing.

NOTE: This fixture is intended to be conduit 

connected to a properly installed and properly 

grounded metal weatherproof junction box (not 

included). All conduit connectors, conduit, and 

junction boxes (sold separately) should be cULus 

Listed suitable for wet locations

.

1. 

Turn off the power at the main fuse/breaker box.

2. 

Using the pattern on the box, mark and drill holes for mounting.

NOTE:

 Mount this fixture in an upright and level position.

3. 

Install the two bottom mounting screws (D) first, leaving enough room between the 

mounting screws and the mounting surface to accommodate mounting the fixture.

4.

  Screw the top mounting screw (D) into the predrilled hole and back the screw out. 

This will leave the hole threaded and make installation of the fixture easier.

5. 

Remove the cover plate by loosening the two mounting screws (E) inside the  

cover plate.

6.

  Remove access cover (C) from fixture (A). Install the first conduit connector and 

conduit (sold separately) into the access cover (C) (Fig. 1).

7.

  Feed supply wires into conduit. Attach ground wire that is attached to fixture 

housing (A) to the junction box earth ground wire.

8.

  Connect the black fixture wire to the black supply wire (hot) with UL-approved wire 

connector (G). Connect the white fixture wire to the white supply wire (neutral) with  

UL-approved wire connector (G).

 NOTE:

 Be careful to connect the wires correctly. Make sure no bare strands of wire 

extend  from the wire nut or other approved wire connectors (G).

9.

   Place the fixture (A) on the two lower mounting screws (D) and install the upper 

mounting screw (D). Tighten all mounting screws to secure the fixture (A).

ITEMS REQUIRED

 

(Purchase separately)

• 

Phillips screwdriver

• 

Adjustable wrench or ratchet wrench with 10mm socket

• 

Drill with 3/16 in. drill bit

• 

1/2 in. diameter flexible conduit (if applicable, length depends on application)

• 

1/2 in. watertight conduit connectors (if applicable)

• 

Wire connectors

IMPORTANT SAFETY INSTRUCTIONS

When using product, basic precautions should always be followed, including the 

following:

• 

Heed all warnings, including below warnings AND those included on product.

• 

Save these instructions and warnings

• 

For outdoor use only.

• 

cULus LISTED for wet location.

• 

Disassembling your fixture will void the warranty.

• 

Your fixture is prewired and preassembled for easy installation.

•  Read and follow these instructions.

• 

Risk of fire/electric shock. If not qualified, consult an electrician.

• 

Disconnect power at fuse or circuit breaker before installing or servicing.

• 

Edges may cut. Handle with care.

• 

Connect fixture to a 120 Volt, 60 Hz power source. Any other connection voids  

  the warranty.

• 

Fixture should be installed by persons with experience in household wiring or  

  by a qualified electrician. The electrical system, and the method of electrically  
  connecting the fixture to it, must be in accordance with the National Electrical  
  Code and local building codes.

• 

Upside down installation can result in overheating or accumulation of water in  

  fixture. Install right side up.

FCC DECLARATION OF CONFORMITY

This device complies with part 15 of the FCC Rules. Operation is subject to the following 
2 conditions: (1) This device may not cause harmful interference, and (2) this device 
must accept any interference received, including interference that may cause undesired 
operation.

 

NOTE: 

This equipment has been tested and found to comply with the limits for a Class B 

digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide 
reasonable protection against harmful interference in a residential installation. This 
equipment generates uses and can radiate radio frequency energy and, if not installed 
and used in accordance with the instructions, may cause harmful interference to radio 

ENGLISH

A.  Fixture housing with light sensor

  Boîtier du luminaire avec détecteur

  de lumière

  Alojamiento del accesorio con

  detector de luz

B.  One-piece lens assembly

  Ensemble de lentille d’une seule pièce

  Ensamblado del lente de una sola pieza

C.  Access cover

  Cache d’accès 

  Cubierta de acceso

D.  (3) ST dia. 0.24*L1.97”  

Mounting screws

  (3) ST dia. 0.24*L1.97 po  

Vis de montage 

  (3) ST dia. 0.24*L1.97 pulg  

Tornillos de montaje

H.  Pole mounting clamp

  Patte pour montage 

sur bras

 Abrazadera para 

montaje de poste

G.  (3) Wire connectors

  (3) Capuchons de connexion 

  (3) Conectores de cables

E.  (2) 1/4-20-1/2” Access cover mounting 

screws (attached to fixture)

  (2) 1/4-20-1/2 po Vis de montage du 

cache d’accès (attached to fixture)

  (2) 1/4-20-1/2 plug Tornillos de la cubierta 

de acceso (conectado al accesorio)

F.  (4) 8-32 1/4” Lens assembly  

lock screws

  (4) 8-32 1/4 po Vis de blocage 

pour assem blage lentille

  (4) 8-32 1/4 plug Tornillos de 

fijación del ensamblado del lente

AL6501LED

Conduit

Conduit

connector

Junction 

box

A

Fig. 1