Description
• Time Delay surface mount fuse capable of replacing
glass tube fuses in certain applications
• Environmentally rugged, complies with EIA-IS-722
Standard
• Solder Immersion Compatible
• Targeted for Consumer Electronics
Agency Information
• UL Recognition Guide & File numbers: JDYX2 & E19180.
• CSA Component Acceptance: 053787 C 000 & Class
No: 1422 30.
Environmental Data
• Life Test: MIL-STD-202, Method 108A, Test Condition D
• Load Humidity: MIL-STD-202, Method 103B
• Moisture Resistance: MIL-STD-202, Method 106E
• Thermal Shock: MIL-STD-202, Method 107D, air-to-air
• Case Resistance: EIA/IS-722
• Resistance to Dissolution of Metallization:
ANSI J-STD-002, Test D
• Mechanical Shock: MIL-STD-202, Method 213B, Test
Condition A
• High Frequency Vibration: MIL-STD-202, Method 204D,
Test Condition D
• Resistance to Solvents: MIL-STD-202, Method 215A
Ordering
• Specify product code and packaging code
Soldering Method
• Wave Immersion: 260°C, 3 sec max.
• Infrared: 260°C, 30 sec max.
2.6
3.0
(0.102)
(0.118)
4.0
(0.157)
8.6
(0.338)
Land Pattern
Dimensions
mm
⁄
(inches)
Brick
™
Fuses
6125TD Series, Time Delay
ELECTRICAL CHARACTERISTICS
% of Amp Rating
Opening Time
100%
4 Hours Minimum
200%
1 Second Minimum
200%
2-4 Seconds Typical
200%
60 Seconds Maximum
SPECIFICATIONS
Product
Voltage
Interrupting
DC Cold
Typical
Typical
Code
Rating
Rating*
Resistance** (ohms)
Melting
Voltage
AC DC
125VAC 60VDC
min.
typ.
max.
I
2
t†
Drop‡
6125TD500mA
125V 60V
50A 50A
.3350 .4025 .4700
0.716
245 mV
6125TD750mA
125V 60V
50A 50A
.2000 .2350 .2700
1.07
250 mV
6125TD1A
125V 60V
50A 50A
.1350 .1680 .2000
2.88
256 mV
6125TD1.5A
125V 60V
50A 50A
.0550 .0630 .0700
2.35
125 mV
6125TD2A
125V 60V
50A 50A
.0380 .0480 .0580
9.45
133 mV
6125TD2.5A
125V 60V
50A 50A
.0280 .0350 .0420
16.2
130 mV
6125TD3A
125V 60V
50A 50A
.0225 .0263 .0300
15.3
97 mV
6125TD3.5A
125V 60V
50A 50A
.0170 .0195 .0220
14.5
95 mV
6125TD4A
125V 60V
50A 50A
.0160 .0185 .0210
38.8
106 mV
6125TD5A
125V 60V
50A 50A
.0115 .0133 .0150
34.4
100 mV
6125TD7A
125V 60V
50A 50A
.0073 .0087 .0100
90.2
99 mV
* AC Interrupting Rating (Measured at designated voltage, 100% power factor); DC Interrupting Rating (Measured at designated voltage, time constant of less than
50 microseconds, battery source)
** DC Cold Resistance (Measured at 10% of rated current)
† Typical Melting I
2
t (Measured with a battery bank at rated DC voltage, 10x-rated current (not to exceed IR), time constant of calibrated circuit less than 50 microseconds)
‡ Typical Voltage Drop (Measured at rated current after temperature stabilizes)
Device designed to carry rated current for four hours minimum. An operating current of 80% or less of rated current is recommended, with further derating required at
elevated ambient temperatures.