background image

Read and 

Retain for 

Future  

Reference

Cooper Bussmann

1050E-T

Unmanaged Ethernet Switch

User Manual

Version 1.1.5

Summary of Contents for 1050E-T

Page 1: ...Read and Retain for Future Reference Cooper Bussmann 1050E T Unmanaged Ethernet Switch User Manual Version 1 1 5 ...

Page 2: ... EXPLOSION HAZARD Do not disconnect equipment unless power has been removed or the area is known to be non hazardous WARNING EXPLOSION HAZARD Substitution of any components may impair suitability for Class I Division 2 WARNING EXPLOSION HAZARD The area must be known to be non hazardous before servicing replacing the unit and before installing WARNING Exposure to some chemicals may degrade the seal...

Page 3: ...ns Failure to follow the instructions can cause personal injury and or property damage Proper Use Any unauthorized modifications to or use of this equipment outside its specified mechanical electrical or other operating limits may cause personal injury and or property damage including damage to the equipment Any such unauthorized modifications 1 constitute misuse and or negligence within the meani...

Page 4: ... Mechanical Specifications 7 1 5 Order Information 7 Chapter 2 GETTING STARTED 8 2 1 Package Contents 8 2 2 Hardware Description 8 Front Panel 8 Top View 8 2 3 Wiring 9 Wiring the Power Inputs 9 Wiring the Fault Alarm Contact 9 Grounding 10 2 4 LED Indications Ports and Cabling 10 LED Indicators 10 Ports 10 Cabling 11 2 5 Mounting Installation 11 DIN rail Mounting 11 Wall Mount Plate Mounting 12 A...

Page 5: ...ly switch to the secondary power input Flexible Mounting The Industrial Switch is extremely compact and can be mounted on a DIN rail or a wall so it is suitable for any space constrained environment Advanced Protection The power line of the 1050E T supports up to 3 000 Vdc EFT Electrical Fast Transient protection which secures equipment against unregulated voltage and makes systems safer and more ...

Page 6: ...02 3u Flow Control and Backpressure IEEE 802 3x Transfer Rate 10 Mbps IEEE 802 3 100 Mbps with Auto Negotiation IEEE 802 3u Fault Alarm Fault Alarm Contact Alarm for System Events 1 Relay Output 1A MAX 24 Vdc or 24 Vac Ethernet Port Connectors RJ 45 Network Cabling 10Base T 2 pair UTP STP Cat 3 4 5 6 cable EIA TIA 568 100 ohm 100m 328 100Base TX 2 pair UTP STP Cat 5 6 cable EIA TIA 568 100 ohm 100...

Page 7: ...Rating 40 C to 75 C 40 F to 167 F Humidity Rating 5 95 RH Non condensing Weight 0 43 kg 0 95 lb Power Supply Nominal Supply 12 Vdc to 48 Vdc Under Over Voltage Protection and Reverse Polarity Maximum Current Draw 450 mA 1 4 Mechanical Specifications The following diagram shows the exterior dimensions of the 1050E T Ethernet switch 1 5 Order Information Item Product Code Description Ethernet Switch...

Page 8: ... Package Contents 1050E T Ethernet Switch x 1 Pluggable Terminal Block x 1 Wall Mounting Plate x 2 2 2 Hardware Description Front Panel The front panel of the 5 port 10 100BaseTX Industrial Switch is shown below Top View The top panel of the 5 port 10 100BaseTX Industrial Switch is equipped with one terminal block connector of two power inputs ...

Page 9: ...r inputs to ensure that the fault alarm is not set Connect V to both pins 2 and 6 and then connect V to both pins 1 and 5 3 Tighten the wire clamp screws to prevent the wires from coming loose Wiring the Fault Alarm Contact The fault alarm contact is in the middle of terminal block connector as shown below The contact will be closed for normal operation and will open in the case of a power failure...

Page 10: ...al ten LEDs display the network status These LEDs are located on the front panel of the switch and are described in the following table LED Color Description P1 Green On Power input 1 is active Off Power input 1 is inactive P2 Green On Power input 2 is active Off Power input 2 is inactive Fault Red On Power input 1 or 2 is inactive Off Power input 1 and 2 are both functional or no power inputs Lin...

Page 11: ...ght through or crossover cabling see the following schematics Cabling Use the four twisted pair Category 5 cabling for RJ 45 port connection The cable length between the switch and the link partner switch hub or workstation must be less than 100m 328 ft 2 5 Mounting Installation DIN rail Mounting The 1050E T ships from the factory with the DIN rail mount kit installed Follow these steps to mount t...

Page 12: ...rack reverse steps above Wall Mount Plate Mounting Follow these steps to mount the switch using the wall mount plate Unscrew the screws to remove the DIN rail mount from the switch 1 Fit the wall mount plates to the top and bottom ends of the switch 2 Use the mounting screws to secure the wall mount plate to the switch 3 Mount using the wall mount holes provided To remove the wall mount plate reve...

Page 13: ...mmunications Full Duplex A full duplex or double duplex system allows communication in both directions and unlike half duplex allows this to happen simultaneously Land line telephone networks are exam ples of full duplex since they allow both callers to speak and be heard at the same time IEEE Institute of Electrical and Electronics Engineers New York www ieee org A membership organization that in...

Page 14: ...www cooperbussmann com wirelessresources Cooper Bussmann 1050E T Unmanaged Ethernet Switch User Manual 14 Notes Rev 1 1 5 ...

Page 15: ...Fax 1 925 924 8502 Online Resources Visit www cooperbussmann com wirelessresources for the following resources and more User Manuals Installation Guides Configuration Software Datasheets Dimensional Drawings North America Latin America 5735 W Las Positas Suite 100 Pleasanton California 94588 USA Telephone 1 925 924 8500 elpro sales cooperindustries com Australia New Zealand Cooper Technology Centr...

Reviews: