To Users

Thank you for selecting 

C&H

 product. Please read this instruction manual carefully before installing and using 

the product, so as to master and correctly use the product. In order to guide you to correctly install and use our 
product and achieve expected operating effect, we hereby instruct as below:

(1)  This equipment should be installed, operated or maintained by the qualified servicemen who have had 

specific training. During operation, all safety issues covered in the labels, User’s Manual and other 
literature should be followed strictly. This appliance can be used by children aged from 8 years and above 
and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge 
if they have been given supervision or instruction concerning used of this appliance in a safety way 
and understand the hazards involved. Children shall not play with the appliances. Cleaning and user 
maintenance shall not be made by children without supervision.

(2)  This product has gone through strict inspection and operational test before leaving the factory. In order to 

avoid damage due to improper disassembly and inspection, which may impact the normal operation of unit, 
please do not disassemble the unit by yourself. You can contact with the special maintenance center of our 
company if necessary.

(3)  For  personal  injury  or  property  loss  and  damage  caused  by  improper  operation  such  as  improper 

installation and debugging, unnecessary maintenance, violation of related national laws and rules and 
industrial standard, and violation of this instruction manual, etc., we will bear no liability.

(4)  When the product is faulted and cannot be operated, please contact with our maintenance center as soon 

as possible by providing the following information.

• 

Contents of nameplate of product (model, cooling/heating capacity, product No., ex-factory date).

• 

Malfunction status (specify the situations before and after the error occurs).

(5)  All the illustrations and information in the instruction manual are only for reference. In order to make the 

product better, we will continuously conduct improvement and innovation. We have the right to make 
necessary revision to the product from time to time due to the reason of sales or production, and reserve 
the right to revise the contents without further notice.

(6)  

The final right to interpret for this instruction manual belongs to 

Cooper&Hunter

.

Summary of Contents for CH-HP10SIRK3

Page 1: ...ce If you have lost the Owner s Manual please contact the local agent or visit www cooperandhunter com Cooper Hunter reserves the right to interpret this manual which will be subject to any change due...

Page 2: ...id damage due to improper disassembly and inspection which may impact the normal operation of unit please do not disassemble the unit by yourself You can contact with the special maintenance center of...

Page 3: ...ss of indoor unit 20 7 4 Outline dimension of indoor unit 21 7 5 Precautions on installation of indoor unit 21 7 6 Water volume and pump capacity with pump 21 7 7 Water volume and expansion vessel pre...

Page 4: ...35 19 Wring Diagram 37 19 1 Control board 37 19 2 Electric wiring 43 20 Commissioning 46 20 1 Check before startup 46 20 2 Test run 47 21 Daily Operation and Maintenance 48 21 1 Recovery 49 21 2 Deco...

Page 5: ...of the unit for longer life and reliable operation If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard The...

Page 6: ...on nameplate of unit and capacity of power supply power cord or socket is suitable for input power of this unit Special circuit must be adopted for power supply to prevent fire Do not use octopus mult...

Page 7: ...thing the unit must be earthed reliably The earthing wire should connect with special device of buildings If not please ask the qualified personnel to install Furthermore don t connect earth wire to g...

Page 8: ...use stop of the unit and even fire Keep pressurized spray gas holder and so on away from the unit above 1m It may cause fire or explosion Please note whether the installation stand is firm enough or n...

Page 9: ...connection under overvoltage category III conditions the instructions shall state that means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules This applian...

Page 10: ...o stop supplying power to the unit Don t directly expose the unit under the corrosive ambient with water or dampness Don t operate the unit without water in water tank The air outlet inlet of unit can...

Page 11: ...Item Minimum entering water pressures Maximum entering water pressures Cooling 0 05MPa 0 25MPa Heating Water heating The range of external static pressures at which the appliance was tested add on he...

Page 12: ...uick water heating 8 Holiday mode 9 Forced Operation Mode 10 Quiet mode 11 Disinfection mode 12 Weather dependent Operation 13 Floor debugging 14 Air removal of the water system 15 Other thermal Cooli...

Page 13: ...e heater of water tank runs When the setting temperature or water tank is reached the e heater will stop running Quick water heating in quick water heating mode the unit runs according to the water h...

Page 14: ...ed on the following conditions Indoor Water Temperature 30 C 35 C Outdoor Air Temperature 7 C DB 6 C WB b 2 Capacities and power inputs are based on the following conditions Indoor Water Temperature 2...

Page 15: ...off valve By pass valve field supplied Notes a The two way valve is very important to prevent dew condensation on the floor while cooling mode b Type of thermostat and specification should be complie...

Page 16: ...pass valve field supplied Notes a The two way valve is very important to prevent dew condensation on the floor while cooling mode b In this case three way valve should be installed and should be compl...

Page 17: ...ondensation on the floor and FCU while cooling mode b In this case three way valve should be installed and should be complied with installation of this manual c Anitary water tank should be equipped w...

Page 18: ...14 5 Main Components 5 1 Indoor unit 1 CH HP6 0SIRK External Plate Heat Exchanger Control Box Expansion Tank Water Pump Flow Switch 3 Way Valve Safety Valve Electric Heater Automatic relief valve Wate...

Page 19: ...32 15 2 CH HP8 0SIRK CH HP10 0SIRK External Plate heat exchanger Water pressure gauge Safety valve 3 way valve Flow switch Automatic relief valve Electric heater Water pump Control panel Expansion tan...

Page 20: ...Heat Pump Unitherm 3 R32 16 5 2 Outdoor unit 1 CH HP6 0SIRK External DC Fan Motor Control Box Compressor Internal 2 CH HP8 0SIRK CH HP8 0SIRK External DC Fan Motor Compressor Control Box Internal...

Page 21: ...mpleted 6 2 Installation of outdoor unit 6 2 1 Select installation location of outdoor unit 1 Outdoor unit must be installed on a firm and solid support 2 Outdoor unit shall be installed close to the...

Page 22: ...luded angle between the rope when hanging and moving must be 40 below to prevent center of the unit from moving 2 Adopt M12 bolts components to tighten feet and under frame when installing 3 Outdoor u...

Page 23: ...to support the weight of air conditioner unit 3 Drainage pipe is easy to connect out 4 Indoor and outdoor connection pipes are easy to go outdoors 5 Do not install at a place where inflammable or expl...

Page 24: ...ttaching indoor unit to the wall Wall Thermal baffle NOTENote While lifting the indoor unit at least two persons should be joined Weight of the indoor unit is more than 50kg The indoor unit must be in...

Page 25: ...2 Keep the indoor unit away from heat sources like heat sink and so on in the room as much as possible 3 Keep the indoor unit as close as possible to outdoor unit Level distance between connection pip...

Page 26: ...djustment is not required c Minimum total water volume is 20 liter d To adjust pre pressure use nitrogen gas by certificated installer 7 8 Selection of expansion vessel Formula V Volume of expansion v...

Page 27: ...ng its weight to other units 8 2 Installation of protective layer on connection pipe 1 To avoid condensate dew or water leakage on connecting pipe the air pipe and liquid pipe must be wrapped with hea...

Page 28: ...Outdoor unit A A A Indoor unit Oil bend Model Pipe size Diameter Length B Elevation A Additional refrigerant gas Liquid Standard Max Standard Max 1 2 1 4 5m 20m 0m 15m 16g m CH HP6 0SIRK 1 2 1 4 5m 20...

Page 29: ...iability in the operation Oil trap should be installed every 5 7 meters when the location of outdoor unit is higher than indoor unit 9 Remote Air Temperature Sensor Front side Back side Remote Air Tem...

Page 30: ...about the remote air temperature sensor Do not connect external electric loads Wire 220V AC should be used only for the electric thermostat Never connect external electric loads such as valves fan co...

Page 31: ...for common 2 Flow A means water flow from the indoor unit to under floor water circuit 3 Flow B means water flow from the indoor unit to sanitary water tank Follow steps below to wire the 3 way valve...

Page 32: ...xpansion vessel T liquid pipe T gas pipe Optional E heater 3 way valve Flow switch Water pump T water out PE T optional water sensor Heating DHW Indoor Unit Step 2 Electric wiring work Other thermal L...

Page 33: ...ob Liquid valve Gas valve Connection pipe Pressure meter 4 After confirming that there is no leakage from the system when the compressor is not in operation charge additional R32 working fluid with sp...

Page 34: ...rigerant recovery will quit 7 Turn off the power supply circuit breaker remove the gauge manifold and then disconnect the refrigerant pipes WARNING When pumping down the refrigerant stop the compresso...

Page 35: ...e appointed after sales service center to purchase a specialized wire with sufficient length 18 Installation of Insulated Water Tank 18 1 Installation measure The insulated water tank should be instal...

Page 36: ...L 70 R2 cm R is inside radius of the pipe Moreover heat preservation should be conducted and metal pipe cannot be used For the first use water tank must be full of water before the power is on 18 2 Ou...

Page 37: ...ion of circulating water inlet outlet pipes connect the water inlet of the unit with circulating outlet of water tank and water outlet of unit with circulating inlet of water tank 4 Installation of wa...

Page 38: ...le 030059000120 Water inlet pipe sub assy 2 05332800002 Drainage Pipe Rubber 1 70814016 Pipe Hoop 13 1 Fix the drainage pipe 2690280000502 Extruded strip 1 Fix the water tank and avoid the damage appe...

Page 39: ...to make the power terminal in the cabinet free from an external force 10 Power cable must be grounded reliably 18 4 2 Specification of power supply wire and leakage switch Power cable specifications...

Page 40: ...used at 40 C and resistible to 90 C see IEC 60364 5 52 If the working condition changes they should be modified according to the related national standard h The specifications of the breaker listed in...

Page 41: ...3 To the ground X20 E heater of water tank X21 E heater 1 X22 E heater 2 X23 Other thermal by 220VAC X24 Reserved X25 Reserved X26 Reserved X27 2 way valve 1 is normally open X28 2 way valve 1 is norm...

Page 42: ...ctric heater 1 CN22 Detection to welding protection for the optional electric heater 2 CN23 Detection to welding protection for the water tank electric heater CN24 Gate control detection CN25 Flow swi...

Page 43: ...4 economizer outlet 5 6 defrosting CN9 485 2 communication without 12V 3 pin CH HP8 0SIRK3 CH HP10SIRK3 CN4 CN3 CN18 CN19 CN15 CN16 CN10 CN9 CN8 CN20 CN21 CN22 CN23 CN24 CN25 X27 X28 X29 X30 X31 X32...

Page 44: ...N16 20K temperature sensor refrigerant vapor line CN16 10K temperature sensor leaving water for the optional electric heater CN16 Rreserved CN8 Water tank temperature sensor CN9 Remote room temperatur...

Page 45: ...4 way valve VA 1 E heater of chassis HEAT E heater of cranke DC MOTORO Reserved DC MOTORO1 Fan motor FA EXV 1 FB EXV 2 T_SENSOR2 1 2 environment 3 4 discharge 5 6 suction T_SENSOR1 1 2 economizer inle...

Page 46: ...N AC L W V U L OUT N OUT Silk Screen Introduction AC L Live line input N Neutral line input L OUT Live line output N OUT Neutral line output COMM Communication U To compressor phase U V To compressor...

Page 47: ...43 19 2 Electric wiring 19 2 1 Wiring principle Refer to Section 18 4 19 2 2 Electric wiring design The wiring diagram stuck to the unit always prevails 1 Wiring diagram indoor unit CH HP6 0SIRK3 CH...

Page 48: ...Heat Pump Unitherm 3 R32 44 2 Wiring diagram outdoor unit CH HP6 0SIRK3 CH HP8 0SIRK3 CH HP10SIRK3...

Page 49: ...e dotted line box requires on site wiring PE PE Electrical box 19 2 3 Terminal board CH HP6 0SIRK3 CH HP8 0SIRK3 CH HP10SIRK3 14 15 13 10 11 9 Teminal board XT3 12 16 L N 1 2 Terminal board XT1 Power...

Page 50: ...ipe proper 8 Are the nilometer of water tank water temperature indicator controller manometer pressure relief valve and automatic discharge valve etc installed and operated properly 9 Does power suppl...

Page 51: ...irstly Recheck the phase sequence before start up to avoid reverse rotation of the compressor which may damage the unit 4 Apply the universal electric meter to measure the insulation resistance betwee...

Page 52: ...check to the working condition of each part to see if there is oil stain at pipeline joint and charge valve to avoid leakage of refrigerant If malfunction of the unit is out of control of users pleas...

Page 53: ...t shall be returned to the refrigerant supplier in the correct recovery cylinder and the relevant Waste Transfer Note arranged Do not mix refrigerants in recovery units and especially not in cylinders...

Page 54: ...r assistance Checks to electrical devices That capacitors are discharged this shall be done in a safe manner to avoid possibility of sparking that no live electrical components and wiring are exposed...

Page 55: ...ation and should be securely fastened The drain hose should be led naturally downward into the floor drain without any convex bow intertwist or fold Extra length of the drain hose inside the floor dra...

Page 56: ...uld be power on 8 hours before operation starts so as to preheat the outdoor compressor 4 Precautions for Freeze Protection in Winter Under subzero climatic conditions in winter anti freeze fluid must...

Page 57: ...ion Oregon USA www cooperDesigned by Cooper Hunter International Corporation Oregon USA C H reserves the right to interpret this manual which will be subject to any change due to product improvement w...