background image

25

Controlling and Operation

Note:

:Fault code

:Fault name

:Occurrence time of the fault,Day, month and year   hour: second (s)

:Click this key to clear all fault records

5.3. Color Display Calibration

Keep click quickly at the blank area on any interface till you hear a long beep. Then you 
will enter the calibration interface. Click "+" to start calibration.
When you hear the beep again, you will finish calibration and exit

Summary of Contents for CH-HP07UMPNK

Page 1: ...r air to water heat pump please read this installation owner s manual carefully before operation and retain it for future reference Installation Owner s manual Air to water heat pump AIR TO WATER HEAT...

Page 2: ...3 Installation occasions 4 4 Water loop connection 4 5 Installation space 4 6 Water tank selection 4 7 Power supply connection 4 8 Cable and switch 4 9 Trial running 5 Controlling and Operation 5 1 Fu...

Page 3: ...nce or improve the product when it is needed without prior notification to the users of this device For information Necessary reading When the product is delivered to the users please check whether th...

Page 4: ...isted action need to be taken ATTENTION include WARNING Please pay attention to what is indicated To prevent the users and others from the harm of this unit and avoid damage on the unit or other prope...

Page 5: ...something wrong or strange smell the power supply need to be shut off to stop the unit Continue to run may cause electrical short or fire Move and repair Entrust Prohibit Entrust When the heat pump ne...

Page 6: ...basement Please check the installation basement in a period one month to avoid any decline or damage on the basement which may hurt people or damage the unit Fix the unit Installation Place Need circu...

Page 7: ...for heating so that there is no burning no waste no dirty gas thus maintain good environment for human and save earth from waste 2 Serve people by high efficiency and money saving The heat pump is dri...

Page 8: ...rall information of the heat pump 6 3 3 Heat pump dimension and view Unit Model CH HP07UMPNK 4 14 382 445 630 1048 605 Wire controller High pressure gage Water outlet DN25 water inlet DN25 58 335 95 1...

Page 9: ...W H Heating Capacity Heating Capacity Cooling Capacity Power Input for Heating Power Input for Cooling Power Supply Compressor Quantity Compressor Type Fan Quantity Fan Power Input Fan Rotate Speed N...

Page 10: ...Overall information of the heat pump 8 Heating Perfomance curve...

Page 11: ...project Fresh Water Water level controller Return pipe form user Solenoid valve Water Tank Sensor S1 S2 Drainage DN20 Showers Hot water supply water pumps Hot water circulating water pumps DN50 Outle...

Page 12: ...Installation 10 Floor Heating Radiator Fan Coil Tap Water Electric heater Tap Water 3 way valve Tem Sensor Water Tank Water Tank 4 1 3 The connection diagram of hot water and space heating project...

Page 13: ...the heat pump is from 15 43 Please do not use lake water river water or untreated ground water for our heat pump Running condition Defrosting When there is frost formed on the unit heat pump will ent...

Page 14: ...e damaged There must be enough space around the unit for maintenance The place is free from heat radiation and other fire flame There must be not obstacles near the air inlet and outlet of the heat pu...

Page 15: ...re that the wiring and action of the switch is normal and controlled by the controller Try to avoid air stayed inside of the water pipe and there must be air vent on the top point of the water loop Th...

Page 16: ...stance between these two parts 1 when the heat pump is installed under basement indoor other confined space please pay attention to the air inlet outlet for CH HP07UMPNK cycled air volume should no le...

Page 17: ...ort The distance from recycled water port to the bottom of water tank is at least 100mm 2 Please make sure that there is insulation for water tank to make sure that the temp decreasing is no more than...

Page 18: ...upply voltage must in line with rated voltage Power supply circuit must be equipped with an All pole disconnect device have at least 3mm contact opening distance The wiring must be completed by profes...

Page 19: ...l the screws are fastened the wiring is made in line with the diagram and the earthing is connected Trial running When the water pump runs for 1 minutes the compressor will start Hear whether there is...

Page 20: ...ntrolling and Operation 5 1 Function of wire controller 1 Power on interface 2 Starting up interface Remark the wire controller can display the temperature unit as or according to the unit model you b...

Page 21: ...epresents not Note is defrosting icon the machine is in defrosting mode when this icon is shown is hot water mode icon this machine is in hot water mode when this icon is shown is heating mode icon th...

Page 22: ...2 Usage of wire controller 1 In shutting down interface on off key is in gray status press on off key can start up the machine 2 Note In starting up interface on off key is in red status press on off...

Page 23: ...2 tapping heating mode icon then the display will enter this mode interface 3 tapping cooling mode icon then the display will switch to this mode interface Note If what you have purchased is a heating...

Page 24: ...as following Key name Key number Key function Tapping this key can back to the main interface Return key Enter key Delete key Tapping this key to undo the last action Note means the new target temp u...

Page 25: ...23 Controlling and Operation 5 Fast heating 6 Timer setting Click the timer setting key to enter the timer setting and the interface display is as follows...

Page 26: ...Minute of timer on Minute of Timer on is shown Hour of Timer on is shown Enable the timer off Enable the timer on Click this key to start or turn off the timed start up function Click this key to sta...

Page 27: ...hour second s Click this key to clear all fault records 5 3 Color Display Calibration Keep click quickly at the blank area on any interface till you hear a long beep Then you will enter the calibratio...

Page 28: ...The system 1 pressure Sensor is broken or short circuit The temp Sensor is broken or short circuit The temp Sensor is broken or short circuit The temp Sensor is broken or short circuit The temp Sensor...

Page 29: ...E29 Syst1 Antifreeze US Use side water system temp is low 1 Check the US water temp or change the temp Sensor 2 Check the pipe water flow and whether water system is jammed or not 1 Check the US water...

Page 30: ...AI DI 14 AI DI 13 AI DI 12 AI DI 11 AI DI 10 AI DI 09 AI DI 08 AI DI 07 AI DI 06 AI DI 05 AI DI 04 AI DI 03 AI DI 02 AI DI 01 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 09 08 07 06 05 0...

Page 31: ...e EVI inlet of system 1 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 Water output temperature Water intput temperature System...

Page 32: ...AI DI 4 AI DI 5 AI DI 6 AI DI 7 AI DI 8 0 5V_IN1 0 5V_IN2 0 5V_IN3 0 5V_IN4 5V GND GND GND GND GND GND GND GND GND GND GND GND GND 1 2 3 4 5 6 7 8 9 10 11 12 13 CN3 CN2 CN1 4 GND 3AI 10 50K 2 GND 1AI...

Page 33: ...ndled separately from domestic waste must be taken to a recycling centre for electric and electronic devices or handed back to the dealer when purchasing an equivalent appliance 1 6 Directive 2002 95...

Page 34: ...line MCB Creepage protector Signal line 2 n 0 5mm Nameplate maximum current Earth line No more than 10A 20A 32A 40A 40A 63A 80A 100A 125A 160A 225A 250A 280A 2 1 5mm 2 2 5mm 2 4mm 2 6mm 2 10mm 2 16mm...

Page 35: ...water supply for house garden Small HVAC circulation system 1 4 Mechanical connection Functional needs Definitions and values Inlet Thread 1 25mm Outlet Thread 1 25mm Weight 7 kg Packing 285 185 225...

Page 36: ...ature 90 C Resist to pressure PN4 Storage and shipping conditions 20 C to 60 C 2 PERFORMANCES 3 QUALITY REQUIREMENTS Functional need Definition and values Product Name PUN 200EH Product Label WILO Mot...

Page 37: ...Code 20170818 0001...

Reviews: