![Cookson Speedline Technologies Electrovert Bravo 8105 Preventive Maintenance Manual Download Page 27](http://html1.mh-extra.com/html/cookson/speedline-technologies-electrovert-bravo-8105/speedline-technologies-electrovert-bravo-8105_preventive-maintenance-manual_2660435027.webp)
. . . . .
S A F E T Y I N F O R M A T I O N
Attach Machine Lock-Out Tag-Out Device
2-9317-372-00-0
Bravo™ 8105 Preventive Maintenance Guide
1-15
Attach Machine Lock-Out Tag-Out Device
Introduction
Refer to the following procedure to isolate and identify all machine energy
sources. As soon as all energy sources are isolated and turned to the Off or Stop
position, notify affected personnel, and attach the lock-out tag-out device and
proceed with the required maintenance, assembly, calibration, or repair. When all
work is complete, the person who attached the lock-out tag-out device is
responsible to notify affected personnel and remove the device.
Safety
To ensure personal safety and avoid equipment damage, observe the following:
Electrical Hazard
Electrical current used can kill. DO NOT TOUCH live electrical components inside
the electrical enclosure. These procedures must be performed only by an
authorized electrician, electrical engineer, or service technician familiar with
testing live voltage.
ATTENTION
If procedures must continue past the shift of the person who applied the lockout
device, ensure that an employee who is working the next shift applies their
lockout device and the previous person removes the initial lockout device.
1. Locate the main power disconnect switch at the Unload End of the system.
2. Turn the main disconnect switch to the OFF position.
3. Pull the tab and insert the lock-out device.
4. Secure the lock-out device in place.
5. Disconnect and bleed the compressed air connections.
6. The system is ready for maintenance, installation, upgrade, or repair proce-
dures.