background image

P r o p e r   U s e

02323‑2

02323‑2 締め付けトルクを妙徳標準に変更

02304‑1

C a u t i o n

Thank  you  for  purchasing  a  CONVUM  product.Please  read  this 
instruction  manual  carefully  and  make  sure  that  you  understand 
its operation procedure before using the product.This manual is 
important for later reference,so please keep it in good hands.

Remote Ultra Small Pressure Sensor Head MPS‑8 Series

Instruction Manual

■Model Index

■Output

■External view

■Circuit

■Specifications

MPS−①8②−AG−③④

④Connector option

  X:no connector、 E:EI connector

③Cable length option

  X:2m、 1:1m、 0.3:0.3m、 5:5m

Cable spec・・G:Grommet

Output ・・・・A:Analog output DC1‑5V
②Pressure port・・A:M5 open,no tap
          B:M5 open,with tap
          C:M5 with tap
          U:Universal joint
          T:φ6 one touch fitting
          T4:φ4 one touch fitting
Series No. ・・8 Silcon diaphragm type 

      Remote Sensor Head

①Pressure range

  V:Vacuum(‑101〜0kPa)、R:Compound(‑101〜500kPa)

pressure

Vacuum   :  0kPa     → →     ‑101kPa  

Compound :‑101kPa     → →     +500kPa   

Linearity 0.5% of F.S.

[V]

O

u

t

p

u

t

 

v

o

l

t

a

g

e

M

a

i

n

 

C

i

r

c

u

i

t

Brown:+V(DC10.8V〜30V)

Black:Analog output(DC1‑5V)

Blue:0V

500Ω

Diaphragm

Working Fluid

Pressure Range

Proof Pressure

Accuracy

Thermal Error

Analog Output

Power Supply

Current Consumption

Circuit Protection

Operating Temp.

Humidity

Noize Resistance

Vibration Resistance

Shock Resistance

Voltage Resistance

General Protection

Material

Cable Connection

Weight

  

±1% of F.S. or less

±2% of F.S. or less at 25℃ in range of 0〜+50℃

1−5V(1V±0.04〜5V±0.04)Linearity 0.5% of F.S. or less

DC10.8〜30V, RIpple(Vp−p) 10% max.

20mA or less

Reverse Voltage Protection

0〜50℃

35〜85%RH(no frozen)

Vp−p400V、 10ms,by 0.5μs Noize sumilator

10〜55Hz,sub‑amplitude which 1.5mm X,Y,Z directions 2 hours

1000m/s

2

(appx.100G) X,Y,Z each direction 3 times

AC1000V 1min. at a totalcover of a charging part

IP40

Grommet:φ3,3 wires

Vacuum 

(V)

−101〜0kPa

0.5MPa

Compound 

(R)

−101〜500kPa

0.8MPa

A/B/C/U:about 6g, T/T4:about 4g

(excl. cable)

Body         :PC

(Polycarbonate)

Pressure Port:A/B/C(Aluminium),T/T4(PC),

            U(Port:PC,M5:Bronze)

Silicon diaphragm

Air and Non‑Corrosive Gases

【Option】AMP EI connector housing

14

14

5.8

Pin No.5
    4
    3
    2
    1 

Housing type:171822‑5 AMP
Switch type :170204‑1 AMP

Pin No.    Lead wire
  1   Brown +V(DC10.8〜30V)
 2   Blue 0V
 3   Black Analog output(DC1‑5V)
 4   No Connection
 5   No Connection

Specification is subject to change for improvement.

4.75

20

1

0

CONVUM

MPS‑V8

■A:M5 open hole(no tap)

■B:M5 open hole(with tap)

■C:M5(tap)

■U:M5 Universal joit

■T:φ6 one touch fitting

■T4:φ4 one touch fitting

1

6

M5 open
Pressure inlet

20

M5 open
Pressure inlet

10

2‑φ3.5

2

1

M5 open
Pressure inlet

4

10

M5 open
Pressure inlet

M5‑6

Pressure inlet

2‑φ3.2

4

10

1

6

Gasket

8

4

1

0

.5

2

0

.9

M5

Pressure inlet

10

9

1

8

6

10

9

1

2

4

●This product is used for pressure confirmation,not for safeguard against 
  accidents or the like.
●Do not put the cable parallel to high‑tension cable or power line,which may 
  cause a malfunction.
●Use sealed wire cable when the distance between Sensor Head and Display 
  unit is over 5m.
●For connecting/disconnecting EI connector,lift up the lever to avoid 
  exccesive force to the Sensor Head.

●Operating environment
 Do not use this product in a place exposed to explosive or inflammable gas.
●Source valtage 
 Avoid overload beyond the source voltage and do not charge AC100v because 
  it may burn the product. 
●When connecting this Sensor Head to Pressure Sensor Display Unit,switch off 
  the power supply of the Display Unit.After making sure proper wiring and 
  connector,switch on the Display Unit.Improper wiring may cause the damage 
  for Display Unit.
●When installing the Sensor Head,fix firmly the pressure port to avoid 
  excessive force to the main body of the Sensor Head.Tightening torque of M5 
  thread of the pressure port should be 1.5〜2.0N・m(approx. 15〜20kgf・cm).
●Do not insert needle etc. into the pressure port to contact the diaphragm 
  to avoid the damage of diaphragm.

Reviews: