background image

IIT

TE

EM

Q

QT

TY

P

PA

AR

RT

T N

N0

0.. 

D

DE

ES

SC

CR

RIIP

PT

TIIO

ON

N

C2614806 

CARRIAGE PLATE, WELDED, 6.20

C2614807 

CARRIAGE PLATE, WELDED, 10.10 & 10.20

C2614809 

CARRIAGE PLATE, WELDED, 20.10 & 20.20

C6012002 

ASSEMBLED,GUIDE ROLLER RST CPL

C6012005 

DISC ø 39 x 6 RST

C2014008 

LOCKING BLOCK, CARRIAGE PLATE

C6015226 

LOCKING BLOCK RST

C6012006 

DOOR STOP, RST

C2013004 

HINGE, LOWER, WELDMENT, DOOR

11 

C8006057 

SCHNORR LOCK WASHER

C8006063 SCHNORR-LOCK 

WASHER

10 

C8006060 

SCHNORR LOCK WASHER

11 4  C8004057 

NUT, 

HEX

12 

C8005050 

WASHER, 8.4 A2 DIN 125

13 

C8003058 

HEXAGON BOLT, M8 X 35

14 

11 

C8003043 

HEXAGON BOLT M6x16

15 

C8013002 

FILLISTER HEAD SCREW DIN 912 - M8X25

16 

C8008095 

BLIND RIVET NUT M6 ROUND

17 

C8001073 

HEXAGON SOCKET SCREW M6x16

18 2  C8004040 

HEXAGON 

NUT 

19 

C2014004 

LOCKING PLATE, CARRIAGE, LOWER PART

20 

C8005041 

WASHER 6.4 A2 DIN 9021

21 

A/R 

C7004014 LOCTITE 

638

22 

C8003066 

BOLT, HEX HD, M10x30, 6.20, 10.10 & 10.20

C8013000

BOLT, HEX HD, M10x25, 20.10 & 20.20

A

E

D

D

E

B

C

INSTALLED

ORIENTATION

SECTION E-E

DETAIL C

DETAIL B

DETAIL A

SECTION D-D

4

1

1920

8

14

7

21

13 21

4

2

16

1

8

20

11 21

10

17

17

22

14 21

39

6

15

5

814

4

18

C2614801 B, C2614802 B & C2614804 P1

0706

SLIDING PLATE, COMPLETE

ALL 6.20

 &

10.10 MODELS

 

      

Page 1 of 2

59

Summary of Contents for OGB-6.20

Page 1: ...Combination Oven Steamer MODELS Gas 10 10 and 6 20 OGB 10 10 OGS 10 10 OGB 6 20 OGS 6 20 0706 1333 East 179th St Cleveland Ohio U S A 44110 Phone 216 481 4900 Fax 216 481 3782 Visit our web site at w...

Page 2: ...th Cleaning 28 29 10 10 Gas Injection with Cleaning 30 31 6 20 Gas Generator with Cleaning 32 33 6 20 Gas Injection with Cleaning 34 35 Component Panel OGB 6 20 10 10 36 37 Component Panel OGS 6 20 10...

Page 3: ...models 57 Door OES 6 20 10 10 58 Sliding Plate all models 59 60 Exterior Sheeting all models 61 Stand Closed Base all models 63 Assemblies Stacking Kits Gas Models 6 20 on 6 20 or 10 20 6 10 on 6 10 o...

Page 4: ...ING THIS MANUAL For caster equipped Combis Per separate instructions connect the strain relief restraining device and complete any remaining installation procedures BEFORE starting the Combi Convother...

Page 5: ...d it is the responsibility of the owner and installer to comply with these codes Cleveland Range equipment is built to comply with applicable standards for manufacturers including UL ANSI NSF ASME Ntl...

Page 6: ...sheet pans For further information contact your Convotherm by Cleveland sales representative or Cleveland Range 2 Serial Number and Equipment Record During manufacture Combis are assigned individual...

Page 7: ...plumbing codes 3 Installation instructions must be read in their entirety before starting installation of a Combi 4 Install the Combi according to the policies and procedures outlined in this manual...

Page 8: ...g and experience lifting heavy equipment to place Combis on supporting surfaces and lift and handle Combis and acessories WARNING All clearance requirements above below and around the Combi are the sa...

Page 9: ...the utility connections and to help reduce the risk of electric shock 10 The strain relief restraining device must be installed to limit the movement of the appliance without depending on the connect...

Page 10: ...32 connection for controlling one unit with a PC personal computer Memory module automatically saves unit settings and recipes Manual program override feature for operational settings Smooth action ha...

Page 11: ...re and health codes Agency Approvals UL Gas UL Sanitation NSF Standards Electrical Requirements 120 volt 11 7 amps 60 Hz single phase Gas Connection 3 4 NPT Gas Type Natural Gas Propane optional Gas F...

Page 12: ...cally saves unit settings and recipes Manual program override feature for operational settings Smooth action hand shower for compartment cleaning Injection system for steam Options and Accessories Con...

Page 13: ...20 frying baskets no wire racks needed For Banquet Operations Optional Plate Rack holds 32 plates Unit Dimensions Width 41 04 Depth 34 50 Height 45 68 Shipping Dimensions Width 47 Depth 41 Height 54 i...

Page 14: ...Manual program override feature for operational settings Smooth action hand shower for compartment cleaning Gas Fired Steam Generator Quiet high efficiency power burner heating system Built in automa...

Page 15: ...e and health codes Agency Approvals UL Gas UL Sanitation NSF Standards Electrical Requirements 120 volt 11 7 amps 60 Hz single phase Do not connect to a G F I outlet Gas Connection 3 4 NPT Gas Type Na...

Page 16: ...ompartment cleaning Injection system for steam Options and Accessories ConvoClean automatic compartment washing system PC HACCP software for establishing HACCP controls and automatic documentation of...

Page 17: ...x 1 steam table pans 14 12 x 20 frying Baskets no wire racks needed For Banquet Operations Optional Plate Rack holds 42 plates Unit Dimensions Width 52 26 Depth 43 24 Height 36 82 Shipping Dimensions...

Page 18: ...ure 2 Press key 19 and rotate Selector Dial 23 to set cooking time OR 1 Press key 20 and rotate Selector Dial 23 to set core temperature ALL 1 Press key 6 to start the Combi 2 To change the settings w...

Page 19: ...Combi Hot Air and Steam Oven temperature is continuously variable between 212 F and 482 F 4 Hot Air Oven temperature is continuously variable between 86 F and 482 F 5 Retherm Oven temperature is cont...

Page 20: ...lapsed cooking time when using Core Temperature mode 20 Core Temperature Set the nominal core temperature See the actual or nominal core temperature See the actual core temperature during cooking time...

Page 21: ...er i Use only genuine Convotherm by Cleveland and Cleveland Range cleaning and descaling products Follow the instructions and heed and obey the warnings on the labels Other products can cause injury p...

Page 22: ...e the Combi from service and contact your qualified Cleveland Range authorized service representative at once c Clean the interior of the of the double glass doors daily 1 Release the quick action loc...

Page 23: ...take effect 3 Rinse thoroughly with the hand shower g Clean the drain and make sure that it is not blocked h Clean the demoisturizing tray trough shaped area under the drain cover i Clean the door dr...

Page 24: ...al to select Cleaning 8 Confirm by pressing the Smart Key 9 Confirm Yes with the Smart Key The semi automatic cleaning process starts 10 Semi automatic cleaning uses cooking modes to assist the cleani...

Page 25: ...minutes followed by a Signal Tone 15 Turn OFF the Combi when the Signal Tone sounds 16 Use the hand shower to rinse thoroughly the oven chamber accessories and behind the fan guard 17 In the case of...

Page 26: ...NVOClean and blue or white hose for CONVOCare A See P N 260AZA Instructions for CONVOClean System Start up Kit for hose attachment solution mixing and other information B The CONVOClean Automatic Clea...

Page 27: ...he magnetic door switch 19 Close the door 20 The self test water supply open appears in the display If the water supply is on open then the self test question disappears from the display a If water su...

Page 28: ...roduct may cause a burning sensation to eyes or skin 6 Emergency and First Aid Procedures In case of eye contact immediately flush eyes with plenty of water If irritation persists seek medical attenti...

Page 29: ...akes approximately 3 hours to complete Do NOT heat the Combi during descaling 1 Turn ON the Combi at the Control Power Service Disconnect switch located below the hand shower 2 Turn ON the Combi with...

Page 30: ...compartment through the steam port or until the descaling port overflows water required varies depending on the Model to rinse descaler from the area above the normal water fill level 14 Replace the...

Page 31: ...61 23 47 50 18 64 58 14 2 1 41 54 12 13 46 42 6 25 20 66 11 30 39 26 53 49 52 5 3 67 65 45 10 15 24 4 63 9 27 29 40 28 60 8 62 7 59 33 31 32 57 38 37 35 36 39 34 56 17 43 55 22 19 21 44 16 1010 GAS GE...

Page 32: ...X 13mm OD X 0 8mm THICK 30 1 111540 NUT HEX M10 X 1 5 DIN 934 STAINLESS STEEL 31 4 C8006060 SCHNORR LOCK WASHER 32 4 C8005050 WASHER 8 4 A2 DIN 125 33 4 C8004057 NUT HEX M8 A4 34 4 C6015213 SPACER MO...

Page 33: ...0706 51 12 17 55 26 50 59 21 1 49 45 6 44 16 13 14 20 46 47 19 2 28 23 61 11 33 42 30 32 43 31 57 8 27 24 22 25 15 28 52 62 7 18 60 48 10 9 36 34 35 53 41 40 38 39 42 37 58 54 5 4 3 1010 GAS INJ W CL...

Page 34: ...0 29 1 C2114634 CORNER WELDED REAR LEFT 10 10 10 20 30 1 111544 WASHER BELLEVILLE M10 SMOOTH TYPE 301 SST 10 21mm ID X 24mm OD X 1 85mm THICK 31 1 111543 RING RETAINING EXTERNAL 1 4 STAINLESS STEEL WA...

Page 35: ...7 48 22 59 54 15 60 17 1 26 28 5 2 27 64 11 12 53 6 56 58 57 51 40 38 39 50 44 41 46 45 55 20 43 42 23 19 63 33 35 34 46 21 37 36 9 8 25 52 13 49 7 18 29 24 30 32 22 3 61 65 4 14 10 31 16 62 620 GAS G...

Page 36: ...111544 WASHER BELLEVILLE M10 SMOOTH TYPE 301 SST 10 21mm ID X 24mm OD X 1 85mm THICK 34 1 111543 RING RETAINING EXTERNAL 1 4 STAINLESS STEEL WALDES 5100 25H 35 1 111542 WASHER BELLEVILLE M8 SERRATED...

Page 37: ...0706 49 50 24 17 55 19 1 28 30 5 2 29 53 13 14 6 7 60 57 42 40 41 56 46 43 48 47 54 22 45 44 25 21 61 35 37 36 48 23 39 38 11 10 27 58 15 51 9 20 31 26 32 34 22 3 59 62 4 16 12 33 18 52 620 GAS INJ W...

Page 38: ...OVER PANEL DISAPPEARING DOOR RST 6 20 32 1 C2114798 BRACKET HIGH LIMIT STEAM GENERATOR 33 1 19993 SWITCH ROCKER DPDT ON OFF 15A 125V 34 1 C5001041 SAFETY TEMPERATURE LIMITER 340 C 35 1 111544 WASHER B...

Page 39: ...ASSEMBLY Gas OGB 6 20 10 10 MODELS 29 28 30 36 33 37 32 19 19 3 19 24 26 25 27 19 16 19 35 11 9 12 10 12 14 15 14 15 18 17 8 38 33 41 48 48 18 16 40 44 43 4 7 17 18 6 16 2 42 5 49 1 49 45 40 3 19 13 3...

Page 40: ...4009 TERMINAL BLOCK SPRING LOADED 1 5 MM2 BLUE 23 1 C4014008 COVER FOUR WIRE 2 5 MM2 24 1 C4014024 TERMINAL FEED THROUGH 4 MM2 25 1 C4014016 TERMINAL GROUNDED SPRING LOADED 2 5 MM2 26 1 C4014023 TERMI...

Page 41: ...BLY GAS OGS 6 20 10 10 MODELS 45 39 40 3 19 13 33 29 28 30 33 36 33 32 19 20 12 37 21 34 22 21 22 23 19 3 19 24 26 25 27 19 16 19 35 11 9 12 10 12 14 15 14 15 18 17 39 8 38 33 41 48 18 16 31 40 44 43...

Page 42: ...2 C4014009 TERMINAL BLOCK SPRING LOADED 1 5 MM2 23 1 C4014008 COVER FOUR WIRE 2 5 MM2 24 1 C4014024 TERMINAL FEED THROUGH 4 MM2 25 1 C4014016 TERMINAL GROUNDED SPRING LOADED 2 5 MM2 26 1 C4014023 TER...

Page 43: ...SELECTOR COMBI 6 10 C8009030 SPACER CONTROL PANEL 7 1 C7011010 GASKET FRONT PLATE 8 10 C6005254 NUT KNURLED 9 1 111588 LABEL CONTROL PANEL STEAM GEN WITH PICTO 1 111590 LABEL CONTROL PANEL SPRITZER WI...

Page 44: ...WASHER 4 3 DIN 125 14 7 C8013004 HEXAGON BOLT M4 X 10 13 3 C8003029 MLF SCREW M5x10 12 1 111551 TRAY DRIP FAN REAR ELECTRIC GAS INJ 6 10 10 10 11 1 111522 TRAY DRIP FAN FRONT 6 20 20 20 10 10 10 2 11...

Page 45: ...1 TRAY DRIP FAN REAR ELECTRIC GAS INJ 6 10 10 10 12 3 C8003029 MLF SCREW M5x10 13 7 C8013004 HEXAGON BOLT M4 X 10 14 5 C8005021 WASHER 4 3 DIN 125 15 1 C5215897 CABLE HARNESS ILLUMINATION 16 1 C201614...

Page 46: ...CTRICAL LIQUID TIGHT 13 1 C5016002 LOCKNUT M25 15 5 C8005021 WASHER 4 3 DIN 125 16 7 C8013004 HEXAGON BOLT M4 X 10 17 1 111522 TRAY DRIP FAN FRONT 6 20 20 20 10 10 18 1 111524 TRAY DRIP FAN REAR 6 20...

Page 47: ...AY DRIP FAN FRONT 6 20 20 20 10 10 15 1 111524 TRAY DRIP FAN REAR 6 20 20 20 16 1 C2116092 BOX AIR INTAKE 17 1 C2016126 ASSY WATER VALVE GAS 6 20 18 1 C2114626 COVER BOTTOM PUMP HOUSING 19 3 C8003029...

Page 48: ...8013004 HEXAGON BOLT M4 X 10 15 5 C8005021 WASHER 4 3 DIN 125 16 4 C8003035 HEXAGON BOLT M5X10 17 1 C70016603000 EDGE PROTECTOR CUT 3 000 18 1 C5215897 CABLE HARNESS ILLUMINATION 19 1 C2616451 BOTTOM...

Page 49: ......

Page 50: ...OSE CONNECTION 3 8 WITH SEAL 2 2 111647 CLAMP OETIKER S S 19 32 3 1 11149811000 HOSE SILICONE 3 8 ID X 11 000 4 1 300455 VALVE ASSEMBLY 1 WAY 120 VAC 5 1 300407 FILTER ELECTRICAL 6 2 300509 TERMINAL 1...

Page 51: ...RE REGULATING VALVE ODGAS 6 2 C6015401 BARB 1 2 R X 3 8 HOSE 7 1 C6015232 CONNECTION NOZZLE 0 6MM 6 20 10 10 10 20 8 1 C6006140 GAUGE 60 PSI BOTTOM MOUNT 9 1 C5009063 PUSH BUTTON SWITCH INJ CHANGE OVE...

Page 52: ...ESSURE REGULATING VALVE ODGAS 6 2 C6015401 BARB 1 2 R X 3 8 HOSE 7 1 C6015232 CONNECTION NOZZLE 0 6MM 6 20 10 10 10 20 8 1 C6006140 GAUGE 60 PSI BOTTOM MOUNT 9 1 C5009063 PUSH BUTTON SWITCH INJ CHANGE...

Page 53: ...C6006140 GAUGE 60 PSI BOTTOM MOUNT 6 6 111647 CLAMP OETIKER S S 19 32 7 1 C6015232 CONNECTION NOZZLE 0 6MM 6 20 10 10 10 20 8 1 C5009063 PUSH BUTTON SWITCH INJ CHANGE OVER CONTACT 9 2 300407 FILTER EL...

Page 54: ...TRIPLE SOLENOID VALVE 110 120V 50 60 Hz 180 2 5 111498 HOSE SILICONE 3 8 ID SPECIFY LENGTH 3 6 111647 CLAMP OETIKER S S 19 32 4 1 111646 TEE BRASS 3 8 BRASS CLEANING CLEANING DEHUMIDIFICATION STEAM GE...

Page 55: ...IO ON N 1 1 300456 VALVE ASSY 2 WAY 120VAC 2 2 111498 HOSE SILICONE 3 8 ID SPECIFY LENGTH 3 2 111647 CLAMP OETIKER S S 19 32 4 2 300407 FILTER ELECTRICAL 5 4 300509 TERMINAL 18 22 AWG PIGGY BACK 4 3...

Page 56: ...E SILICONE 3 8 ID SPECIFY LENGTH 5 10 111647 CLAMP OETIKER S S 19 32 6 1 111646 TEE BRASS 3 8 BRASS 7 1 C5001085 PRESSURE REGULATING VALVE ODGAS 8 2 C6015401 BARB 1 2 R X 3 8 HOSE 9 1 C6015232 CONNECT...

Page 57: ...GENERATOR 8 1 C6005260 SEAL THERMOCOUPLE SENSOR OSC OSP 9 1 C6015040 FLAT GASKET FOR DOUBLE LEVEL PROBE 10 1 C2314974 FLANGE INSPECTION STEAM GENERATOR 11 15 C8017011 NUT FLANGE HEX 12 A R C7014000 CO...

Page 58: ...D DE ES SC CR RI IP PT TI IO ON N 1 1 C6015100 DRAIN ELBOW FOR STEAM GENERATOR 2 1 C6005299 SUPPORT BUSHING STEAM GENERATOR PUMP 3 1 C8009057 WIRE CLAMP D 36 BLACK 4 1 300506 DRAIN PUMP WITH 110 V MOT...

Page 59: ...EALING RING GAS SCREEN 15 1 C2615367 FLANGE BURNER 16 1 C5015004 INSPECTION GLASS BURNER 17 1 C2614845 COVER INSPECTION GLASS BURNER 18 2 C6015039 SEAL INSPECTION GLASS BURNER 19 5 C8012001 SCREW M5x1...

Page 60: ...NECTION CABLE BUSHING BURNER INSERT 9 2 C2614849 LINING PLATE ELECTRODE GAS 11 1 C2614842 CLAMPING FLANGE BURNER HL 50 10 2 C6015039 SEAL INSPECTION GLASS BURNER 12 1 C6015032 SEAL BURNER 50 MM 13 1 C...

Page 61: ...M5x12 FILLISTER HD TORX 8 1 C6016023 AUTOMATIC FIRING DEVICE 110V AUTO IGNITION 9 1 C6016025 COVER AUTOMATIC FIRING DEVICE 10 1 C2616516 GAS HOSE 580mm LG PREASSEMBLED 6 20 1 C2616517 GAS HOSE 780mm L...

Page 62: ...MBLY INNER DOOR 10 10 3 1 C6012000 DOOR HANDLE LOCKING 4 1 C6009016 PLASTIC LETTER C RED 5 2 C8015000 MLF SCREW M6X8 6 1 C2514430 UNHINGING SAFEGUARD DOOR 7 1 C8001024 SCREW FILISTER HD M4x10 DIN 7985...

Page 63: ...R LOCK WASHER 10 5 C8006060 SCHNORR LOCK WASHER 11 4 C8004057 NUT HEX 12 1 C8005050 WASHER 8 4 A2 DIN 125 13 1 C8003058 HEXAGON BOLT M8 X 35 14 11 C8003043 HEXAGON BOLT M6x16 15 4 C8013002 FILLISTER H...

Page 64: ...L C DETAIL B DETAIL A SECTION D D 4 1 19 20 8 14 7 21 13 21 4 2 16 1 8 20 11 21 10 17 17 22 14 21 3 9 6 15 5 8 14 4 18 C2614801 B C2614802 B C2614804 P1 0706 SLIDING PLATE COMPLETE ALL 6 20 10 10 MODE...

Page 65: ...GS 10 10 OEB 10 10 OES 10 10 4 1 C2114762 PANEL ASSY REAR OGB 6 20 1 C2114742 PANEL ASSY REAR OGS 6 20 OEB 6 20 OES 6 20 1 C2114763 PANEL ASSY REAR OGB 10 10 1 C2114743 PANEL ASSY REAR OGS 10 10 OEB 1...

Page 66: ...I STAND 6 10 10 10 8 4 111673 HINGE COMBI STAND 9 1 111674 CATCH MAGNETIC COMBI STAND 10 2 110492 SCREW 6 32 X 0 312 PAN HD PHILLIPS SST 11 3 104080 SCREW TR PHH 8x1 2 TYPE B SST 12 24 111686 SCREW 10...

Page 67: ......

Page 68: ......

Page 69: ......

Page 70: ......

Page 71: ...20 1 C2016206 FLUE PIPE HOT AIR STACKING KIT 6 10 11 4 06162 FOOT 6 00 ADJUSTABLE FLANGED TRI BOLT HOLE PATTERN 12 20 C8001024 SCREW FILISTER HD M4x10 DIN 7985 14 1 05250 ELBOW 90 1 2 NPT BRASS USED F...

Page 72: ...E PATTERN 6 3 C8001024 SCREW FILISTER HD M4x10 DIN 7985 7 1 111703 AIR DUCT STACKING KIT x 10 8 1 05250 ELBOW 90 1 2 NPT BRASS 9 1 05253 ELBOW STREET 90 1 2 NPT BRASS 10 1 14335 NIPPLE 0 500 NPT X 4 0...

Page 73: ...eam Burner Control N21 The 12 VDC Power Supply G1 12 VDC is sent to terminals 1 and 2 of connector X20 on the Gas Board A20 12 VDC is sent to terminal 3 and 4 of connector X10 on the Control Board A10...

Page 74: ...minals 5 6 7 and 8 on connector X10 to terminals 3 4 5 and 6 of connector X28 on the Gas Board A20 The Gas Board A20 begins the steam generator heat circuit A signal is sent from terminal 8 of connect...

Page 75: ...ined the signal is sent from terminal 2 of connector X2 on the Steam Power Burner and Fan Control U21 to terminal 9 of connector X24 on the Gas Board A20 A request for heat is sent from terminal 3 of...

Page 76: ...erature is less than 212 degrees F than fan will be pulsed on for 2 seconds every 60 seconds after the cabinet set temp B6 e Hot air heat circuit is energized A signal is sent from terminal 2 of conne...

Page 77: ...nder the Combi symbol When the heat circuit is energized the heat symbol will be energized The cooking mode symbol will be energized The time display will invert and begin to count down b The fan circ...

Page 78: ...tor X2 on the Hot Air Power Burner and Fan Control U20 to terminal 3 of connector X24 on the Gas Board A20 A request for heat is sent from terminal 3 of connector X20 on the Gas Board A20 to terminal...

Page 79: ...ond coast NOTE If the set temperature is less than 212 degrees F than fan will be pulsed on for 2 seconds every 60 seconds after the cabinet set temp B6 d The steam generator heat circuit is energized...

Page 80: ...e is energized allowing gas and air into the burner chamber to be ignited by the hot surface igniter The Hot Air Burner Control Module N20 senses at least 1 5 micro amps DC from the flame sensor P1 at...

Page 81: ...DATE SHEET OF REV DRAWN BY DRAWING NO THIS DESIGN DESCRIBES A PROPRIETARY ITEM AND IS THE PROPERTY OF CLEVELAND RANGE THIS DRAWING IS NOT TO BE COPIED OR USED WITHOUT THE APPROVAL OF CLEVELAND RANGE T...

Page 82: ...18 RPM BU 18 RD 18 BM1 X13 6 X13 5 BU 18 MOTOR DRIVE SH V2 WH V1 BU U2 RD W1 BN TW GY TW GY X13 2 X13 1 L1 N1 L N GND Z1 LINE FILTER GR BU 12 BK 12 3 2 1 3 2 1 BN BK RD 6 5 4 6 5 4 BK 18 BK 18 BK 18 2...

Page 83: ...3 5 1 2 C7 D5 A10 X10 12 A10 X10 11 D4 A10 X10 10 D4 A10 X10 9 D4 IDENTIFICATION MODULE 2 F4 BU 18 BU 18 22 X10 5 A1 RD YL B8 X10 20 FBS2 6 Y2 Y3 Y21 FBS2 6 FBS2 6 X10 23 RD 18 GND X10 100 MODULE X39...

Page 84: ...U10 12V U10 COM PHASE L1 RESET CONVECTION 1 RESET CONVECTION 1 HL1 HEAT REQUEST HL1 ALARM CONVECTION 1 ALARM CONVECTION 1 SPEED CONVECTION 1 PWM CONVECTION 1 GROUND CONVECTION 1 CONVECTIO 1 FLAME OK G...

Page 85: ...10 GND RD 18 24 VAC STB BU 18 RD 18 RD 16 RD 16 BU 16 OR 16 120VAC BK 16 WH 16 FLAME SENSOR P1 GND FLAMECHECK NEUTRAL RESET CONV 1 HL1 HI LIMIT HI LIMIT RESET AIR HEAT GO RESET AIR HEAT BURNER SUPPLY...

Page 86: ...1 1 4 B5 4 B5 4 B5 GN 18 RD 18 BU 18 BU 18 RD 18 RD 18 A20 X24 9 A20 X24 8 A20 X24 7 34 GND FLAMECHECK NEUTRAL RESET AIR HEAT GO RESET AIR HEAT ALARM STEAM GEN DE BURNER SUPPLY 120V PWM STEAM GEN SPEE...

Page 87: ...11 9 B5 8 C4 CONTROL POWER S1 15A F10 F1 1 STEAM HOT AIR F E D C B A 1 2 3 4 5 6 7 8 F E D C B A 1 2 3 4 5 6 7 8 CLEVELAND RANGE LLC 1333 East 179th St Cleveland Ohio 44110 2574 VOLTAGE WATTAGE CURRE...

Page 88: ...AT ALARM HOT AIR 1 X25 X21 X25 10 X25 2 9 6 X21 X26 4 3 1 1 3 4 2 5 U10 X12 11 9 X25 9 6 22 MOTOR DRIVE 21 22 21 N21 7 Hi Limit PHASE L1 Hi Limit RESET AIR HEAT NEUTRAL FLAMECHECK 1 2 3 4 5 6 7 GND X1...

Page 89: ...5 L1 110 120 VAC INPUT 2 3 HOT AIR OVEN LAMP X10 1 12 11 10 IDM RD IDM BU 8 7 RESET TxD_12V 9 IDM BK 5 6 4 GND 0VDC IN RxD_12V 2 3 1 12VDC IN 12VDC FAN 12VDC FAN SM 5010 CONTROL BOARD A10 N L1 12 0 12...

Page 90: ...VDC Power Supply G1 12 VDC is sent to terminals 1 and 2 of connector X20 on the Gas Board A20 12 VDC is sent to terminal 3 and 4 of connector X10 on the Control Board A10 To terminal 2 of connector X1...

Page 91: ...sent from terminal 2 of connector X2 on the Hot Air Control Module N20 to the hot surface igniter R20 The gas valve is energized allowing gas and air into the burner chamber to be ignited by the hot...

Page 92: ...and Fan Control U20 to terminal 2 of connector X15 on the Control Board A10 A request for heat is sent from terminal 3 of connector X12 on the Control Board A10 to terminal 10 on connector X1 on the...

Page 93: ...mbustion blower When this speed is attained the signal is sent from terminal 2 of connector X2 on the Hot Air Power Burner and Fan Control U20 to terminal 2 of connector X15 on the Control Board A10 A...

Page 94: ...minals 5 6 7 and 8 on connector X10 to terminals 3 4 5 and 6 of connector X28 on the Gas Board A20 c The Gas board A20 Transmits a signal from terminal 4 of connector X26 to the Motor Drive The motor...

Page 95: ...A10 to the coil of the Y3 solenoid allowing water to be thrown against the element until the bypass probe B5 senses 183 degrees F The heat circuit will remain energized until the cabinet set temperat...

Page 96: ...DATE SHEET OF REV DRAWN BY DRAWING NO THIS DESIGN DESCRIBES A PROPRIETARY ITEM AND IS THE PROPERTY OF CLEVELAND RANGE THIS DRAWING IS NOT TO BE COPIED OR USED WITHOUT THE APPROVAL OF CLEVELAND RANGE T...

Page 97: ...X13 6 X13 5 BU 18 MOTOR DRIVE SH V2 WH V1 BU U2 RD W1 BN TW GY TW GY X13 2 X13 1 L1 N1 L N GND Z1 LINE FILTER GR BU 12 BK 12 3 2 1 3 2 1 BN BK RD 6 5 4 6 5 4 BK 18 BK 18 BK 18 2 1 9 8 7 3 9 1 2 3 7 8...

Page 98: ...E 2 F4 BU 18 22 X10 4 A1 X10 20 FBS2 6 Y2 Y3 Y21 FBS2 6 FBS2 6 X10 23 GND X10 100 MODULE X39 1 PICTO OPTION OPERATION BOARD A12 A11 BM 5010 IDM BK IDM BU IDM RD IDM WH TxD RxD GND 0VDC IN 12VDC FAN 12...

Page 99: ...BK 16 WH 16 FLAME SENSOR P1 GND FLAMECHECK NEUTRAL RESET CONV 1 HL1 HI LIMIT HI LIMIT RESET AIR HEAT BURNER SUPPLY 120V GROUND CONVECTION 1 SPEED CONVECTION 1 PWM CONVECTION 1 N L1 GND GND F E D C B A...

Page 100: ...ITHOUT THE APPROVAL OF CLEVELAND RANGE TITLE SIZE B WIRING DIAGRAM OGS 6 20 10 10 300494 120VAC 10 25W 11 7A DRL 8 9 05 5 6 A PRELIMINARY RECIEVE TRANSMIT GND 1 3 4 L N PE 2A 1 2 3 RD LINE FILTER FAN...

Page 101: ...2 3 4 1 5 6 8 7 PICTO X39 1 X18 9 10 1 X19 1 MODULE A12 OPERATION MODULE A11 BM 5010 Y22 Y23 Y20 Y21 X13 8 10 9 FREE FREE L2 5 7 L1 6 PUMP RINSE 2 3 4 6 1 X11 8 7 BURNER SUPPLY 4 5 2 3 I D MODULE Y2 Y...