Layout and function
User manual
23
Electrical installed load ratings
The following table shows the electrical installed load ratings:
OES
6.10
6.20
10.10
10.20
12.20
20.10
20.20
Table-top applian-
ces
Floor-standing
appliances
3~ 400V 50/60Hz (3/N/PE)
Rated power consumption
[kW]
11,4 19,8 19,8 34,3 34,3 39,6 68,5
Convection power
[kW]
10,5
18,9 18,9 33,0 33,0 37,8 66,0
Motor power
[kW]
0,8
0,8 0,8 1,2 1,2 1,7 2,4
Rated current
[A]
15,3
26,3 26,3 47,6 47,6 52,4 95,0
max. permissible system
impedance Z
sys
[
Σ
]
0,627 0,252 0,252 0,113 0,113 0,125 -
Fuse
[A]
16 35 35 50 50 63 100
recommended conductor
cross-section*
[mm
2
]
5G4 5G6 5G6 5G16 5G16 5G16 5G35
Heat output
latent [kJ/h]
2100
3500 3500 6400 6900 6900 12200
sensible
[kJ/h]
2500 4500 4500 7800 7800 8900 15400
3~ 230V 50/60Hz (3/PE)
Rated power consumption
[kW]
11,7 20,1 20,1 34,6 34,6 40,1 69,1
Convection power
[kW]
10,5
18,9 18,9 33,0 33,0 37,8 66,0
Motor power
[kW]
0,8
0,8 0,8 1,5 1,5 2,2 3,0
Rated current
[A]
27,2
46,2 46,2 83,5 83,5 92,3 166,9
max. permissible system
impedance Z
sys
[
Σ
]
0,239 0,151 0,151 -
-
-
-
Fuse
[A]
35 50 50 100 100 100 200
recommended conductor
cross-section*
[mm
2
] 5G6
5G16 5G16 5G35 5G35 5G35 5G95
3~ 200V 50/60Hz (3/PE)
Rated power consumption
[kW]
11,7 20,1 20,1 34,6 34,6 40,1 69,1
Convection power
[kW]
10,5
18,9 18,9 33,0 33,0 37,8 66,0
Motor power
[kW]
1,1
1,1 1,1 1,5 1,5 2,2 3,0
Rated current
[A]
30,8
52,7 52,7 95,4 95,4 105,2 190,6
max. permissible system
impedance Z
sys
[
Σ
]
0,239 0,151 0,151 -
-
-
-
Fuse
[A]
35 63 63 100 100 125 200
recommended conductor
cross-section*
[mm
2
] 5G6
5G16 5G16 5G35 5G35 5G35 5G95
*recommended conductor cross-section for wires laid uncovered in air up to 5 m in length.