4 Controls,
Connectors
and
Indicators
The Convision V6xx A is equipped with various controls, connectors and indicator
lamps (LEDs). These are described below.
4.1 Front
View
Figure 1: Front view of the Convision V6xx A
♦
F button: deletes the hard disk.
♦
LEDs 1-6: these light up when a camera is connected to the corresponding port;
they flash when the respective camera is being accessed.
♦
M button: deletes the configuration.
♦
Online LED: is lit when the Convision V6xx A proactively established a
connection.
♦
Active LED: is lit when the alarm function of the Convision V6xx A has been
switched to "alert".
♦
HD LED : (HD = hard disk); is lit when data is written to or read from the hard disk
(option).
♦
Power LED: lights up as soon as the Convision V6xx A is connected to the power
supply and switched on.
♦
Reset button: when this button is activated, the Convision V6xx A is reset. This
means the Convision V6xx A is rebooted and re-initialized.
Never press F and M together when you switch on the
Convision V6xx A as this would cause the entire software to be
deleted.
Manual
- 9 -