The smoke detector should be installed in the centre of the room, on the 

ceiling, or for  a sloping roof at the highest point, as smoke rises and gathers 
in this area. This guarantees the earliest possible alarm warning.

 

 
Smoke alarms should be installed in all rooms, but not directly above the 
cooking area in the kitchen or the bath, where dust concentrates. 

 
Ensure that the smoke detector is not installed directly on or in the vicinity of 

large metal objects as they can affect the radio range. 

 

 

5. Installation 

 
Please follow these steps to install the Convia smoke detector: 
 

 

At the place where you are going to install the detector, draw a 
horizontal line six inches long. 

 

 

Remove the mounting bracket from your unit by rotating it 
counterclockwise. 

 

 

Place the bracket so that the two longest hole slots are aligned on the 

line. In each of keyhole slots, draw a mark to locate a mounting plug 
and screw. 

 

Remove the bracket. 

 

 

Using a 3/16-inch (5mm) drill bit, drills two holes at the marks and 
insert plastic wall plugs. Put the detector away from  getting plaster 

dust on it when you drill holes for mounting. 

Summary of Contents for Type 3

Page 1: ...Detector Type 3 Operating Instructions Version 1 0 For Marmitek alarm installations of the types Homeguard MS8000 Security System MS9470 Security System MS9770 Protector28 Security System Base Station...

Page 2: ...erpts or duplicated or processed using electronic mechanical or chemical procedures without written permission of the publisher This handbook may contain mistakes and printing errors The information i...

Page 3: ...nce references 5 4 Installation places 5 5 Installation 8 6 Registering the smoke detector with the base stations of the types MS9470 MS9770 SC2700 SC2800 10 7 Registering the smoke detector with the...

Page 4: ...directly on the receiver The development of smoke causes the light to be dispersed by smoke particles and picked up by the receiver In contrast to many products on the market no radioactive substance...

Page 5: ...etectors should be installed in accordance with the NFPA Standard 74 National Fire Protection Association Batterymarch Park Quincy MA 02169 In principle it is advisable to install several smoke detect...

Page 6: ...Page 6 of 12 Recommended best and acceptable locations to mount smoke detectors Locations for placing smoke detectors for single residence with only one sleeping area...

Page 7: ...Page 7 of 12 Locations for placing smoke detectors for single floor residence with more than one sleeping area Arrangement in a building with many floors...

Page 8: ...ge metal objects as they can affect the radio range 5 Installation Please follow these steps to install the Convia smoke detector At the place where you are going to install the detector draw a horizo...

Page 9: ...ot insert the battery at this stage 9V Please follow the steps of the next chapter before you insert the battery How to install the battery The smoke detector requires an alkaline battery Match termin...

Page 10: ...e detector The smoke alarm sends a radio signal to the base station The LED on the sensor illuminates briefly the base station emits a short signal tone as confirmation of reception 4 If you are using...

Page 11: ...lace the battery 9V in the correct polarity in the battery holder of the smoke detector The smoke alarm sends a radio signal to the base station The LED on the sensor illuminates briefly the base stat...

Page 12: ...ted on the ceiling and turned clockwise to the stop 9 Convia smoke detector technical data Frequency 433 92 MHz Modulation AM Range 30 to 50 meters free field Alarm 85 dB Power supply 9V Blockbattery...

Reviews: